Azbil Corporation
Operation using the data setting device
Model MTG11A/18A, MTG11B/18B, MTG14C
5-53
Set a pulse width in accordance with the following procedure:
Step
Procedure
Screen
1
Enter ENGINEERING MODE in accordance with
the entry into ENGINEERING MODE (see
section 5-5-10 : on page 5-36). Then press the
or key to display the screen at right.
2
Press the key to move the cursor to the position
under NUM.
3
Pressing the key switches a screen for entering a
numeric value for pulse width to a screen for
fixing the DUTY ratio to 50%.
4
To enter a numeric value for pulse width, press the
key to return to the screen for the entry of
numeric values. Using the key, move the cursor
to the position under a desired digit to be set.
5
Using the or key, change the value to a desired
value to be set.
6
Press the key to move the cursor to the position
under #.
Press the MODE key to return to the
MEASURING MODE and to save data.
m
CAUTION
You have only ten minutes to return to MEASURING MODE to save the new value before
the system resets it to the previously saved value.
12.3 %
# PLS 27.778 %
010.00ms
WID NUM
12.3 %
# PLS 27.778 %
010.00ms
WID NUM
12.3 %
# PLS
50 %
WID DUTY
12.3 %
# PLS 27.778 %
010.00ms
WID NUM
12.3 %
# PLS 13.889 %
005.00ms
WID NUM
12.3 %
# PLS 13.889 %
005.00ms
WID NUM
CM2-MTG300-2001.book 53 ページ 2015年9月29日 火曜日 午前10時14分
Summary of Contents for MagneW Neo PLUS
Page 16: ...List of Figures Tables CM2 MTG300 2001 book 4...
Page 92: ...MEMO CM2 MTG300 2001 book 38...
Page 106: ...MEMO CM2 MTG300 2001 book 4...
Page 266: ...MEMO CM2 MTG300 2001 book 82...
Page 312: ...MEMO CM2 MTG300 2001 book 46...
Page 336: ...MEMO CM2 MTG300 2001 book 22...
Page 338: ...CM2 MTG300 2001 book 2...