![Azbil MagneW Neo PLUS User Manual Download Page 130](http://html1.mh-extra.com/html/azbil/magnew-neo-plus/magnew-neo-plus_user-manual_3042666130.webp)
Operation using the data setting device
Azbil Corporation
5-24
Model MTG11A/18A, MTG11B/18B, MTG14C
Set the electrode status diagnostic function in accordance with the following procedure.
(To the next page)
Step
Procedure
Screen
1
The screen at right is a screen display example in
MEASURING MODE (measurement state).
2
Press the MODE key.
The OPERATOR'S MODE screen appears for
approx. two seconds, and then the damping setting
screen appears.
3
Press the
Ï
key to display the screen shown on
the right.
4
Press the
Î
key to move the cursor to the OFF
position.
5
Press the
Ï
key to select SENSITIVITY HIGH.
6
Press the
Î
key to move the cursor to the position
under *.
Press the MODE key to return to the
MEASURING MODE, and save the data.
7
Empty the pipe with SENSITIVITY HIGH set to
check if the function detects the empty status. Or,
in case that you find the scale on the electrode, set
the SENSITIVITY HIGH to check the function
detects the scale on electrode status. Perform the
checking when 30 seconds or more have passed,
because it takes at least 30 seconds to detect the
empty status after the pipe becomes empty or
detect the scale on electrode status.
(Result)
When the empty status or scale on electrode is
detected, the screen at right appears.
The “EMPTY OR SCALE ON ELECTRODE”
message is flashing, the analog output and the
pulse output show the output values as selected in
the “Electrode status output mode” table.
20.0 %
01.94 m
3
/h
WP0
00069401
20.0 %
* OPERATOR'S
MODE
20.0 %
* DAMPING
005.0 s
20.0 %
* ELECTRODE_ST
SENSITIVITY OFF
20.0 %
* ELECTRODE_ST
SENSITIVITY OFF
20.0 %
* ELECTRODE_ST
SENSITIVITY HIGH
20.0 %
* ELECTRODE_ST
SENSITIVITY HIGH
0.0 %
EMPTY OR SCALE
ON ELECTRODE
CM2-MTG300-2001.book 24 ページ 2015年9月29日 火曜日 午前10時14分
Summary of Contents for MagneW Neo PLUS
Page 16: ...List of Figures Tables CM2 MTG300 2001 book 4...
Page 92: ...MEMO CM2 MTG300 2001 book 38...
Page 106: ...MEMO CM2 MTG300 2001 book 4...
Page 266: ...MEMO CM2 MTG300 2001 book 82...
Page 312: ...MEMO CM2 MTG300 2001 book 46...
Page 336: ...MEMO CM2 MTG300 2001 book 22...
Page 338: ...CM2 MTG300 2001 book 2...