Chapter 46: Command Line Descriptions
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
1437
configure cable spectrum-group trigger * time
Purpose
Defines the Time of Day trigger.
Default Access Level
15
Command Syntax
configure cable spectrum-group trigger <trigger_id> time <day> <hh:mm:ss>
configure cable spectrum-group trigger <trigger_id> time <day> <hh:mm:ss> no
Supplemental
Information
To delete this trigger condition, use the no option.
Parameters
<trigger_id>
The trigger number and has values of 1-64
<day>
Day of the week. Must use one of the following values:
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Daily
<hh:mm:ss>
Standard 24-hour time, e.g.:
hh = hour and varies from 0 to 23
mm = minutes and varies from 0 to 59
ss = seconds and varies from 0 to 59