Chapter 46: Command Line Descriptions
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
2239
[max-tr-burst
<1522-
4294967295>]
Specifies the token bucket size B (in bytes) for this Service Flow.
[min-res-rate <0-
4294967295>]
Specifies the minimum rate, in bits/sec, reserved for this Service Flow. If CM requests less bandwidth than this minimum, the C4
CMTS may reallocate the excess.
[min-res-pkt <0-
4294967295>]
Specifies an assumed minimum packet size (in bytes) for which the Minimum Reserved Traffic Rate will be provided.
[peak-tr-rate <0-
429296295>]
Specifies peak traffic rate shaped.
[max-burst <0-
4294967295>]
Specifies the maximum concatenated burst (in bytes) which a Service Flow is allowed. This parameter is calculated from the FC byte
of the Concatenation MAC Header to the last CRC in the concatenated MAC frame
[poll-int <0-
4294967295>]
Specifies the nominal interval (in units of microseconds) between successive unicast request opportunities for this Service Flow on
the upstream channel. This parameter is typically suited for Real-Time and Non-Real-Time Polling Service.
[poll-jitter <0-
4294967295>]
Specifies the maximum amount of time that the unicast request interval may be delayed from the nominal periodic schedule
(measured in microseconds) for this Service Flow.
[grant-size <0-
4294967295>]
Specifies the unsolicited grant size in bytes
[grant-int <0-
4294967295>]
Specifies the nominal interval (in units of microseconds) between successive data grant opportunities for this Service Flow. Required
for UGS and UGS/AD
[grant-jitter <0-
4294967295>]
Specifies the maximum amount of time (in microseconds) that the transmission opportunities may be delayed from the nominal
periodic schedule for this Service Flow. Required for UGS and UGS/AD
[grant-per-int <0-
127>]
For UGS, the value of this parameter indicates the actual number of data grants per NominalGrant Interval. For UGS/AD, the value of
this parameter indicates the maximum number of Active Grants per Nominal Grant Interval. This is intended to enable the addition
of sessions to an existing UGS Flow via the Dynamic Service Change mechanism, without negatively impacting existing sessions.
[active-tmout <0-
65535>]
Specifies the maximum duration resources remain unused on an active Service Flow. If there is no activity on the Service Flow within
this time interval, the CMTS will change the active and admitted QoS Parameter Sets to null.
[adm-tmount <0-
65535>]
Specifies the duration that the CMTS will hold resources for a Service Flow’s Admitted QoS Parameter Set while they are in excess of
its Active QoS Parameter Set.