Chapter 14: Cable-side Configuration
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
425
Display Specific MD-US-SG Fiber Nodes
The following command example displays detailed information regarding specific MAC domain upstream signaling group
fiber nodes and their associated service groups and ports:
show cable fiber-node mUSsg 1
An output similar to the following example will occur:
Cable mDSsg/
Fiber Node MAC mCMsg mUSsg Channels
---------------- ----- ----- ------ -----------------------------------------
FN1 1 1 U1 13/0-3
FN1 1 1 D1 1/4-7
FN2 2 1 D1 12/0-3
FN2 2 1 U1 1/8-11
FN3 3 1 D1 11/0-3
FN3 3 1 U1 2/0-3
FN4 4 1 D1 10/0-3
FN4 4 1 U1 2/4-7
FN5 5 1 D1 9/0-3
FN5 5 1 U1 2/8-11
FN6 6 1 D1 8/0-3
FN6 6 1 U1 4/0-3
* Indicates that downstream channel is not primary-capable.
Display All Cable-mac Service Groups
The following command example displays all system cable-macs and associated service groups:
show cable service-group
An output similar to the following will occur:
Cable
MAC mCMsg mDSsg mUSsg
--- ----- ----- -----
1 1 1 1
2 1 1 1
3 1 1 1
4 1 1 1
5 1 1 1
6 1 1 1