Chapter 21: Integrated Upstream Agility
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
681
1 5 749000000 3200000 4
1 6 749000000 3200000 3
Group State Next Trigger
1 1 2 1 degradation snr < 20 AND (ufec_err > 5 OR fec_err > 15)
1 1 2 2 degradation snr < 20 AND (ufec_err >15 OR fec_err > 25)
1 1 6 3 improvement snr > 20 AND ufec_err < 5 AND fec_err < 15
1 1 6 4 improvement snr > 20 AND ufec_err <15 AND fec_err < 25
1 2 3 2 degradation snr < 20 AND (ufec_err >15 OR fec_err > 25)
1 3 4 3 improvement snr > 20 AND ufec_err < 5 AND fec_err < 15
1 4 5 4 improvement snr > 20 AND ufec_err <15 AND fec_err < 25
1 5 6 5 time Fri 12:00:00
1 6 1 6 period 3600
Use the following command to display one or all triggers that have been defined:
show cable spectrum-group trigger [<trigger_ID>]
The system response will take the following form:
Trigger Type
0
Manual
1
degradation ufec_err > 5 OR fec_err > 15 AND snr < 20
2
degradation ufec_err > 15 OR fec_err > 25 AND snr < 20
3
improvement ufec_err < 5 AND fec_err < 15 AND snr > 20
4
improvement ufec_err < 15 AND fec_err < 25 AND snr > 20
5
time Fri 12:00:00
6
period 3600
Use the following command to display the history of state transitions for the state machine associated with each
upstream channel:
show interface cable-upstream <slot/us-port> spectrum-group history [detail]
Where:
slot is the chassis slot number of the CAM. Range = 0-15
us-port is the upstream port of the CAM
detail provides additional reasons for the state transition.
An example of the output of this command is shown below:
P=Periodic T=TOD D=Degradation I=Improvement S=Startup M=Manual
Upstream Cable
Port Mac Time Group State Trigger info
11/0 1 May 9 09:42:42 1 0->1 0(S) , Change ID: 0b:00:0000
11/0 1 May 9 09:43:14 1 1->2 1(P) , Change ID: 0b:00:0001, ChannelWidth 6400000->3200000
11/0 1 May 9 09:43:46 1 2->3 1(P) , Change ID: 0b:00:0002, ChannelWidth 3200000->6400000, ModProfile 27->26