Chapter 6: System Control Module (SCM)
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
193
2.
Back-up the existing configuration with the following command:
copy running-config verbose /system/cfgfiles/backupMMDDYY.cfg
3.
FTP the configuration off the CMTS and save it on a local machine / server. The configuration will be required later.
4.
Power down the C4 CMTS.
5.
Remove the SCM or SCM-II cards from the chassis.
6.
If out-of-band access is used and the Ethernet cables were connected to the front of the old SCM, reconnect them to
the front of the new SCM 3 (or reconnect them to the rear PIC because the SCM 3 will use the rear SCM PIC port for
OOB by default).
7.
Out-of-band SCM Ethernet access defaults to the rear SCM PIC. Depending on your environment, you can choose to
connect to the rear SCM PIC or use step below to use the front Ethernet connector. If you choose to move the cables
to the rear SCM PIC, go to step . If Ethernet cables are used and will remain connected to the front port, continue with
step 8.
8.
Insert the SCM 3 card in slot 19 and connect serial console cable and the front Ethernet cable.
9.
To change the default operation to use the front port, power up the chassis with the SCM 3 card in slot 19. See the
sample bootloader script below. Using the example below, respond as instructed.
Example of Bootloader Script
The bootloader script allows you to reconfigure default parameters.
#####################################################################
To change any of this, press <m> and <RETURN> key within 2 seconds
#####################################################################
Type m followed by the RETURN key within two seconds. If you miss the prompt and fail to enter
Modify mode, then reseat the card to restart the bootloader script.
PASSWORD:
Enable Password Recovery ?[No]
Hit the RETURN key.
REAR ETHERNET INTERFACE PARAMETERS:
Enable the System Controller's ethernet port ? [Yes]
Hit RETURN.
Select ethernet port: 0-Front 1-Rear:[1]
Type 0 followed by the RETURN
key to use the front ethernet port.
IP address for the System Controller ethernet port?[10.44.108.1] Hit RETURN.
Use a subnet mask for the ethernet port interface?[Yes]
Hit RETURN.