Chapter 12: Basic Bring-up Procedure for a C4c CMTS
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
367
The following is an example of the output:
C4# show linecard status
Slot Description Admin Oper Duplex Serial HW Version Prov/Det
State State State Number Type
10 CAM (0D, 12U) Up IS Active 05453CMD0022 CAM-01122W/F09 CAM/CAM
15 CAM (16D, 0U) Up IS Active 08113CSD0005 CAM-20016W/E02 DMM/DMM
17 RCM A Up IS Active 08143RCM0005 RCM-01000W/D02 RCM/RCM
19 SCM A Up IS Active 06063CBM0071 SCM-02440W/B06 SCM/SCM
Show the fiber node database and the topology information:
show cable fiber-node <name>
The following is an example of the output:
C4# show cable fiber-node
Cable mDSsg/
Fiber Node MAC mCMsg mUSsg Ports
---------------- ----- ----- ------ --------------------
FN1 1 2 D1 15/0 15/1 15/2 15/3
FN1 1 2 U1 10/0.0
* Indicates that downstream channel is not primary-capable.
Verify the MAC Domain configuration:
show interface cable-mac <mac>
An example of the
show interface cable-mac
output:
Cable-mac 1
=============
Cable Oper Mod Power Spare LBal
DS Port Mac Conn State Annex Freq(Hz) Type (.1dBmV) Group Group
15/0 1 0 IS B(US) 621000000 q64 500 - 16779264, 16781312, 16783360,
16785408
15/1 1 0 IS B(US) 627000000 q64 500 - 16779264, 16781312, 16783360,
16785408
15/2 1 0 IS B(US) 633000000 q64 500 - 16779264, 16781312, 16783360,
16785408
15/3 1 0 IS B(US) 639000000 q64 500 - 16779264, 16781312, 16783360,
16785408
Cable Oper Chan Channel Mini Mod Power LBal
US PORT Mac Conn State Type Freq(Hz) Width Slot Prof (dBmV) Group
10/0.0 1 0 IS tdma 10000000 3200000 4 2 0 16781312