Chapter 11: Basic Bring-up Procedure for the C4 CMTS
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
333
3. Power Up the Chassis
At this point, power up the chassis. The SCM and RCM are configured automatically and come into service. As the C4 CMTS
is coming up, the system output displays the system activity.
4. Configure Slots
Use the following commands for basic slot configuration:
configure slot 14 type 32DCAM-B
configure slot 15 type 32DCAM-B
configure slot 0 type 24UCAM
configure slot 1 type 24UCAM
configure slot 0 spare-group 0 auto
configure slot 1 spare-group 0
configure slot 15 spare-group 15 auto
configure slot 14 spare-group 15
configure slot 14 no shutdown
configure slot 15 no shutdown
configure slot 0 no shutdown
configure slot 1 no shutdown
5. Configure RCM Ethernet Connections
Enter the following CLI commands to configure the RCM ethernet ports:
configure interface gigabitEthernet 17/0 ip address 192.168.176.2 255.255.255.0
configure interface gigabitEthernet 17/0 no shutdown
configure interface gigabitEthernet 18/0 ip address 192.168.177.2 255.255.255.0
configure interface gigabitEthernet 18/0 no shutdown
This example uses static routing. To apply a default route to the RCMs enter the following commands:
configure ip route 0.0.0.0 0.0.0.0 192.168.176.1
configure ip route 0.0.0.0 0.0.0.0 192.168.177.1
6. Configure MAC Domains
This section configures the MAC Domain on your system.