AltiContact Manager Administration Manual
xxiii
•
Vermeiden Sie das Berühren von nichtisolierten Telefonkabeln oder Terminals, wenn
die Telefonleitung an den Netzschnittstellen nicht abgeschaltet ist.
UL Regulatory Safety Requirements
(Requisitos Reglamentarios de Seguridad de La Asociación de
Aseguradores (UL)/Sicherheitserfordernisse gemäß UL (Underwriter's
Laboratories, Inc.))
Host Computer
1.
Model AltiGen/AltiWare apparatus is approved for connection to Telecommunications
Systems specified in these instructions for use subject to the conditions set out in them.
Any other usage will INVALIDATE this approval.
2.
The host machine shall be “CE” marked, with the internal ISA and PCI slots operating
at SELV in accordance with EN60950, 1992, issue 2, +A4.
3.
This apparatus MUST be professionally installed.
4.
The host machine MUST be hardwired earthed in accordance with EN60950, 1992,
issue 2, +A4, 1997, cl. 6.2.1.2 with an earth wire from the host machine earthing
terminal to the building earth.
5.
The host machine SELV circuit is connected to the protective earthing terminal in
accordance with EN60950 cl. 2.5.
6.
The host machine ISA bus pins B1, B10, or B31 (edge connectors on CPU mother-
board/backplane) MUST be less than 0.1 Ohms to host machine earthing terminal.
7.
AltiGen complies with PCI Board specifications Rev. 2.1 (5V 32-bit).
8.
The power required by the host machine and the total of all adapter cards installed within
the host environment, together with any ancillary apparatus, shall not exceed the power
specification of the host machine.
9.
It is essential that, when other option cards are introduced that use or generate a
hazardous voltage, the minimum creepages and clearances specified in the following
table are maintained. A hazardous voltage is one that exceeds 42.4V peak AC or 60V
DC. If you have any doubt, seek advice from a competent engineer before installing
other adapters into the host machine.
Clearance (mm)
Creepage (mm)
Voltage used or generated by
host or other cards
2.0
2.4 (3.8)
Up to 50 Vrms or Vdc
ISA bus
ISA bus
B1
B10
B31
Summary of Contents for AltiContact Manager Version 4.6
Page 1: ...AltiContact Manager Version 4 6 Administration Manual Revised 06 2003 4413 0001 4 6...
Page 14: ...xii AltiContact Manager Administration Manual Index I 1 Readers Comment Form R 1...
Page 38: ...xxxii AltiContact Manager Administration Manual...
Page 144: ...Stopping the AltiGen Switching Service 4 12 AltiContact Manager Administration Manual...
Page 202: ...Configuring the Triton T1 PRI Board 6 28 AltiContact Manager Administration Manual...
Page 224: ...Outgoing Call Blocking 7 22 AltiContact Manager Administration Manual...
Page 270: ...Setting Dialing Pattern Routing 10 12 AltiContact Manager Administration Manual...
Page 272: ...11 2 AltiContact Manager Administration Manual Example IVR Planning...
Page 290: ...Call Recording 12 8 AltiContact Manager Administration Manual...
Page 352: ...Setting Queue Management Options 14 24 AltiContact Manager Administration Manual...
Page 378: ...Queue Management 15 26 AltiContact Manager Administration Manual...
Page 384: ...Configuration 16 6 AltiContact Manager Administration Manual...
Page 438: ...21 38 AltiContact Manager Administration Manual...
Page 464: ...Changing TAPI Configuration Parameters 23 4 AltiContact Manager Administration Manual...
Page 476: ...DINA Manager 24 12 AltiContact Manager Administration Manual...
Page 544: ...RMA Form B 10 AltiContact Manager Administration Manual...
Page 556: ...G 12 AltiContact Manager Administration Manual...
Page 573: ...Index AltiContact Manager Administration Manual I 17 Index...
Page 574: ...Index I 18 AltiContact Manager Administration Manual...