ACS-CONTROL-SYSTEM GmbH
l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l [email protected]
119
Universal Data Manager
Anhang
119
Description
Condition description when the digital input is not active. This text is both shown in the
display and saved to memory.
Only visible if the result is = control input or state
User entry
Text (max. 6 characters)
Factory setting
Off
Save event
Navigation
Expert → Application → Maths → Maths x → Save event
Direct access code: 400010-00x
Examples: Maths 1: 400010-000; Maths 4: 400010-003
Description
Determines whether the condition change from low to high or high to low is stored in the
event log.
Requires higher memory capacity.
Only visible if the result is = control input or state
Options
No, Yes
Factory setting
Yes
Event message
Navigation
Expert → Application → Maths → Maths x → Event message
Direct access code: 400018-00x
Examples: Maths 1: 400018-000; Maths 4: 400018-003
Description
"Do not acknowledge": No message is shown if the digital input switches.
"Acknowledge": A message window is shown on the screen which has to be acknowledged
by operating a push button.
Only visible if the result is = control input or state
Options
Do not acknowledge, Acknowledge
Factory setting
Do not acknowledge
Event text L->H
Navigation
Expert → Application → Maths → Maths x → Event text L->H
Direct access code: 400011-00x
Examples: Maths 1: 400011-000; Maths 4: 400011-003