Commissioning
Universal Data Manager
34
The Expert menu is protected by the code
"0000"
. If an access code is set up under
"Setup -> Advanced setup -> System -> Security -> Protected by -> Access code"
,
this must be entered here.
You will find
all
settings for the device in the
"Expert"
menu:
Parameter
Possible settings
Description
Direct access
000000-000
Direct access to parameters (fast access)
System
Basic settings that are needed to operate the unit,
(e.g. date/ time, security, memory management,
messages, etc.)
Inputs
Configuration of analog and digital inputs.
Outputs
Settings only required if outputs (e.g. relays or
analog outputs) are to be used.
Communication
Settings required if the USB, RS232/RS485 or
Ethernet interface of the device is to be used (PC
operation, serial data export, modem operation, etc.).
The different interfaces (USB, RS232/RS485,
Ethernet) can be operated in parallel. However,
simultaneous use of the RS232 and RS485
interface is not possible.
Application
Define different application-specific settings (e.g.
group settings, limit values etc.).
Diagnostics
Device information and service functions for a swift
device check.
A detailed overview of all operating parameters can be found in the appendix at the
end of the Operating Instructions. (→ 67)
9.6
Configuration management
You can save the setup data ("Configuration") to an SD card or a USB stick or store
them in a database using the configuration software. This allows additional devices to
be configured very easily using the same settings.
Save setup:
The function used to save the setup files can be found in the main menu under
"Operation -> SD card (or USB stick) -> Save setup"
.
!
CAUTION
If the SD card or USB stick are removed directly:
Risk of data loss on SD card or USB stick
‣
To remove the SD card or the USB stick, always select
"Operation -> SD card (or USB
stick) -> Remove safely"
in the main menu!
9.7
Simulation
Various functions/signals can be simulated for test purposes here.
NOTICE
Selecting Simulation: Simulation of the relays can be found in the main menu under
"Diagnostics -> Simulation". Simulation of the measured values can be found in the
main menu under "Expert -> Diagnostics -> Simulation".
In the Simulation mode only simulated values will be recorded and the intervention is
logged in the event log.
‣
Do not start simulation if measured value recording must not be interrupted!