ACS-CONTROL-SYSTEM GmbH
l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l [email protected]
23
Universal Data Manager
Operation options
23
User role
Typical tasks
Menu
Content/meaning
Fault elimination:
• Diagnosing and eliminating process errors.
• Interpretation of device error messages and
correcting associated errors.
"Diagnostics"
Contains all parameters for detecting and analyzing
errors:
•
Diagnosis list
All the diagnosis messages pending are output.
•
Event logbook
Events such as limit value violations and power
failures are listed in chronological order.
•
Device information
Display of important device information (e.g. serial
number, firmware version, hardware, etc.).
•
Measured values
Display of current measured values of device.
•
Outputs
Current status of outputs (if used).
•
Simulation
Various functions/signals can be simulated for test
purposes here.
Note:
In Simulation mode, normal recording of the
measured values is interrupted and the intervention
is logged in the event log.
•
Initialize modem
Initializes the modem connected to the serial
interface (for automatic call answering).
Expert
Tasks that require detailed knowledge of the
function of the device:
• Commissioning measurements under difficult
conditions.
• Optimal adaptation of the measurement to
difficult conditions.
• Detailed configuration of the communication
interface.
• Error diagnostics in difficult cases.
"Expert"
Contains all parameters of the device (including those
that are already in one of the other menus). The expert
menu is protected by a code. Factory setting: 0000. This
menu is structured according to the function blocks of
the device:
•
"System" submenu
Contains all higher-order device parameters that do
not pertain either to measurement or the measured
value communication.
•
"Inputs" submenu
Contains all parameters for configuring the analog
and digital inputs.
•
"Output" submenu
Contains all parameters for configuring the outputs
(e.g. relays).
•
"Communication" submenu
Contains all parameters for configuring the
communication interfaces.
•
"Application" submenu
Contains all parameters for configuring application-
specific settings (e.g. group settings, limit values
etc.).
•
"Diagnostics" submenu
Contains all parameters for detecting and analyzing
errors.