RAM
Contents
Proc
edure
ServiceUI
08
Suspend when quota is
empty
Sets whether the process is suspended
immediately or suspended after the job is
completed if quota is used up.
0: Suspended immediately
1: Suspended after the job is finished
Setting
mode
System
Counter
9787
0
0~1
1
SYS
08
Service call checking period
setting
0: No checking period specified (= Calls service
technician immediately)
1: 10 minutes
2: 30 minutes
3: 1 hour
4: 6 hours
5: 12 hours
6: 24 hours
7: 48 hours
8: 7 days
9: 1 month
10: 1 year
11: 5 years
12: Not limited (= Calls service technician if such
error has occurred in the past even once or more)
Setting
mode
System
Maintenance
9788
6
0~12
1
SYS
08
Service Notification setting
Enables to set up to 3 E-mail addresses to be sent.
(08-9794, 9607, 9608)
0: Invalid
1: Valid (E-mail)
2: Valid (FAX)
Setting
mode
System
Maintenance
Remote-
controlled service
9793
0
0~2
1
SYS
08
Destination E-mail address 1
Maximum 192 letters
Setting
mode
System
Maintenance
Remote-
controlled service
9794
11
SYS
08
Total counter information
transmission setting
0: Invalid
1: Valid
Setting
mode
System
Maintenance
Remote-
controlled service
9795
0
0~1
1
SYS
08
Total counter transmission
date setting
0 to 31
Setting
mode
System
Maintenance
Remote-
controlled service
9796
0
0~31
1
SYS
08
Temporary communication
password setting
Sets a temporary communication password. The
password can be entered in alphanumeric
characters (A to Z, a to z, 0 to 9) up to 10 digits.
The entered password is displayed with "*" on the
touch panel and the self-diagnostic lists.
(Maximum 10 digits, minimum 5 digits)
Setting
mode
System
Network
9798
99999
11
SYS
08
Switchover of mode
Sets the authentication mode when "0: (Internal
authentication)" is selected in the code 08-9293.
0: Card ID differs from the User ID
1: Card ID is the same as the User ID
Setting
mode
System
User control
Local
authentication
9799
0
0~1
1
SYS
08
Forcible mode change in
toner empty status
0: SLEEP MODE
1: AUTO POWER SAVE
2: READY
Setting
mode
System
Process
9804
0
0~2
1
SYS
08
Firmware version of printer
loader section
Setting
mode
System
Version
Printer
9806
2
-
08
Tray2
Setting
mode
System
Version
Printer
ROM version of
printer optional
tray
9807
0
00.00.00~F
F.FF.FF
14
-
08
Tray3
Setting
mode
System
Version
Printer
ROM version of
printer optional
tray
9807
1
00.00.00~F
F.FF.FF
14
-
77
Ver03
08 Setting Mode
Содержание e-Studio477s
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved DISASSEMBLY AND REPLACEMENT 2 6 ...
Страница 214: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved ERROR CODE AND TROUBLESHOOTING 5 110 ...
Страница 288: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved REMOTE SERVICE 7 42 ...
Страница 318: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 8 30 ...
Страница 332: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 9 14 ...
Страница 338: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 10 6 ...
Страница 437: ...Maintenance Utility Operating Manual 42678819FU02 1 38 Maintenance Utility Operating Manual Version 1 1 ...
Страница 480: ......
Страница 481: ......
Страница 482: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...