e-STUDIO477S/527S
05/08
Mode
Element
Sub Element
Item
Subitem
Code
Sub-
Code
Details
Default
value
Acceptable
value
RAM
Contents
Proc
edure
ServiceUI
05
1st drawer
0: Manual
1: Automatic
Adjustment
mode
Printer
Feeding
system/Paper
transport
Setting method
of drawer size
4800
0
1
0~1
4
SYS
05
2nd drawer
0: Manual
1: Automatic
Adjustment
mode
Printer
Feeding
system/Paper
transport
Setting method
of drawer size
4800
1
1
0~1
4
SYS
05
3rd drawer
0: Manual
1: Automatic
Adjustment
mode
Printer
Feeding
system/Paper
transport
Setting method
of drawer size
4800
2
1
0~1
4
SYS
05
4th drawer
0: Manual
1: Automatic
Adjustment
mode
Printer
Feeding
system/Paper
transport
Setting method
of drawer size
4800
3
1
0~1
4
SYS
05
LCF
0: Manual
1: Automatic
Adjustment
mode
Printer
Feeding
system/Paper
transport
Setting method
of drawer size
4800
4
1
0~1
4
SYS
05
Black
13: -3
14: -2
15: -1
16: 0
17: 1
18: 2
19: 3
Adjustment
mode
Printer
Image control
Density correction Fine adjustment
of density
correction
4903
3
16
13~19
4
SYS
05
Setting of measure against
curl
0: Off
1: On
Adjustment
mode
Printer
Maintenance
4907
0
0~1
1
PU
05
Black
0: -3 1: -2 2: -1 3: 0 4: 1 5: 2 6: 3
Adjustment
mode
Printer
Image control
Fine adjustment
for printing plain
paper
4908
0
3
0~6
4
PU
05
Black
0: -3 1: -2 2: -1 3: 0 4: 1 5: 2 6: 3
Adjustment
mode
Printer
Image control
Fine adjustment
for printing
transparencies
4909
0
3
0~6
4
PU
05
Unevenness of print quality
0: -3
1: -2
2: -1
3: 0
4: 1
5: 2
6: 3
Adjustment
mode
Printer
Image control
Print deviation
correction
4910
0
3
0~6
4
PU
05
Background
0: -3
1: -2
2: -1
3: 0
4: 1
5: 2
6: 3
Adjustment
mode
Printer
Image control
Print deviation
correction
4910
1
3
0~6
4
PU
05
Drum cleaning mode
0: Disabled
1: Enabled
Adjustment
mode
Printer
Maintenance
4911
0
0~1
1
PU
05
PPC
When the value increases by "1", the reproduction
ratio in the primary scanning direction increases by
approx. 0.1%.
Adjustment
mode
Image
Processing
Reproduction
ratio
adjustment
Reproduction
ratio adjustment
of primary
scanning
direction
7000
128
0~255
1
SYS
1
Ver03
05 Adjustment Mode
Содержание e-Studio477s
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved DISASSEMBLY AND REPLACEMENT 2 6 ...
Страница 214: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved ERROR CODE AND TROUBLESHOOTING 5 110 ...
Страница 288: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved REMOTE SERVICE 7 42 ...
Страница 318: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 8 30 ...
Страница 332: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 9 14 ...
Страница 338: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 10 6 ...
Страница 437: ...Maintenance Utility Operating Manual 42678819FU02 1 38 Maintenance Utility Operating Manual Version 1 1 ...
Страница 480: ......
Страница 481: ......
Страница 482: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...