
e-STUDIO477S/527S/477SL
© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved
EXTERNAL COUNTERS
10 - 4
5. BKCTR signal, MNCTR signal, FLCTR signal (output signals)
These signals become “Low” (ON) synchronizing with the CTRON signal according to the copying
mode used. The pulse width corresponds to the fixed time. Though the CTRON signal is set to
“Double count”, they are not outputted synchronizing with the second count signal.
6. SIZE3, SIZE2, SIZE1 and SIZE0 signals (output signals)
These 4 signals are outputted in the combination of 4 sizes for the paper to be copied.
They are the signals for the coin controller, and are outputted from the LGC board.
7. LARGE/SMALL signal (output signal)
When large size paper (A3 / A3 wide / LD) is selected or paper size is not specified with the manual
feeding, it outputs “Low” in real time. In other cases, it outputs “High”. The setting change for large
size paper is performed with F/W.
This is the signal only for the coin controller.
8. FULL COLOR signal (output signal)
If the full color mode is selected, it outputs “Low” in real time. In other cases, it outputs “High”. By
default, it outputs “Low” since it is set as full color mode.
This is the signal only for the coin controller.
9. TWN / MON COLOR signal (output signal)
If the twin color or mono color mode is selected, it outputs “Low” in real time. In other cases, it
outputs “High”. This is the signal only for the coin controller.
10.B/W signal (output signal)
If the black mode is selected, it outputs “Low” in real time. In other cases, it outputs “High”. This is
the signal only for the coin controller.
11.KCTRON signal (output signal)
These signals are synchronized with the electronic counter of the equipment and they become
"Low" when the counter is turned ON. They are the signals for driving a mechanical counter, and
output from the LGC board.
They can drive inductive loads, such as a solenoid, using 24V supplied from the equipment. The
interval between when they are turned ON and when this happens next must be at least 100 ms.
"Single count" or "Double count" can be switched according to the paper size by setting "1" or "2" for
08-6010.
Содержание e-Studio477s
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved DISASSEMBLY AND REPLACEMENT 2 6 ...
Страница 214: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved ERROR CODE AND TROUBLESHOOTING 5 110 ...
Страница 288: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved REMOTE SERVICE 7 42 ...
Страница 318: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 8 30 ...
Страница 332: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 9 14 ...
Страница 338: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 10 6 ...
Страница 437: ...Maintenance Utility Operating Manual 42678819FU02 1 38 Maintenance Utility Operating Manual Version 1 1 ...
Страница 480: ......
Страница 481: ......
Страница 482: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...