© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO477S/527S/477SL
ERROR CODE AND TROUBLESHOOTING
5 - 67
5
[F122] Database abnormality (message/job log management database)
[F124] Language DB damage error
[F130] Invalid MAC address
Classification
Error item
Other service call
Login after the startup fails in any starting mode because log
management database is corrupted.
Check item
Measures
Setting
1. Delete the log in the following procedure: [5] + [C] +
[POWER]
4. Initialize database
2. Log database
(jobs and messages) (Note that all job and message logs
will be deleted.)
2. If the error is not recovered, reinstall the system software.
([4] + [9] + [POWER]
4. System Software(HD data))
Notes:
• If you rebuild the databases with a job remaining,
delete it after finishing.
• When "Rebuilding all databases" is performed, all
data including log/user/role/group/department
information and address book data are deleted. If
you back up the data in advance, they will be
recovered by restoring them after rebuilding the
database.
Classification
Error item
Other service call
Login after the startup fails in any starting mode because
language management database is corrupted.
Check item
Measures
Setting
Delete the journal file: [5] + [C] + [START]
4. Initialize DB
3. Language DB
If the recovery is still not completed, reinstall the system
software and application program.
Classification
Contents
Other service call
Invalid MAC address
Check item
Measures
Setting
This error occurs when the top 3 bytes of the MAC address is
not "00" "80" "91".
SYS board
Replace the SYS board.
Содержание e-Studio477s
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved DISASSEMBLY AND REPLACEMENT 2 6 ...
Страница 214: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved ERROR CODE AND TROUBLESHOOTING 5 110 ...
Страница 288: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved REMOTE SERVICE 7 42 ...
Страница 318: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 8 30 ...
Страница 332: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 9 14 ...
Страница 338: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 10 6 ...
Страница 437: ...Maintenance Utility Operating Manual 42678819FU02 1 38 Maintenance Utility Operating Manual Version 1 1 ...
Страница 480: ......
Страница 481: ......
Страница 482: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...