© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO477S/527S/477SL
REPLACEMENT OF PC BOARDS/HDD
6 - 25
6
Notes:
When the back-up file is restored, do not perform HDD partition creation (Format HDD) before
the normal start-up.
(11) Reinstall the GD-1340 Fax Unit if used.
[F] Clear SRAM update Error flags
(1) Turn the power ON while pressing [3] and the [CLEAR] button simultaneously.
(2) Enter the password, and then press the [OK] button. (If the password is not set for Service, press
the [ENTER] button without entering anything.)
(3) After “Firmware Assist Mode” is displayed on the LCD, check that “1: Clear Error Flag in Software
Installation.” is marked and press the [START] button.
If not, key in [1] and then press the [START] button.
(4) When “Operation Complete” is displayed on the LCD, clearing the flag is completed.
(5) Turn the power OFF.
[G] Backup ADI key
If the ADI-HDD is installed, follow the steps below. To confirm the type of device, start up the equipment
in the 4C mode.
(1) Turn the power ON while pressing [3] and the [CLEAR] button simultaneously.
(2) Enter the password, and then press the [OK] button. (If the password is not set for Service, press
the [OK] button without entering anything.)
(3) Key in [5] to select "5. Key Backup Restore", and then press the [START] button.
(4) Key in [6] to select "6. ADIKey FROM to SRAM", and then press the [START] button.
(5) Wait until the backup of the ADI key is completed. "Operation Complete" is displayed.
(6) Restart the equipment after the backup is completed.
If you want to perform the backup of the license, do not restart the equipment but perform from
(4) in "[H] Backup encryption key".
[H] Backup encryption key
(1) Turn the power ON while pressing [3] and the [CLEAR] button simultaneously.
(2) Enter the password, and then press the [OK] button. (If the password is not set for Service, press
the [ENTER] button without entering anything.)
(3) Key in [5] to select "5. Key Backup Restore", and then press the [START] button.
(4) Key in [2] to select "2. Key FROM to SRAM", and then press the [START] button.
(5) Wait until the backup of the encryption key is completed. "Operation Complete" is displayed.
(6) Restart the equipment after the backup is completed. If you want to perform the backup of the
license, do not restart the equipment but perform from (4) in "[I] Backup license".
(7) Turn the power OFF.
Содержание e-Studio477s
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved DISASSEMBLY AND REPLACEMENT 2 6 ...
Страница 214: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved ERROR CODE AND TROUBLESHOOTING 5 110 ...
Страница 288: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved REMOTE SERVICE 7 42 ...
Страница 318: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 8 30 ...
Страница 332: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 9 14 ...
Страница 338: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 10 6 ...
Страница 437: ...Maintenance Utility Operating Manual 42678819FU02 1 38 Maintenance Utility Operating Manual Version 1 1 ...
Страница 480: ......
Страница 481: ......
Страница 482: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...