e-STUDIO477S/527S/477SL
© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved
FIRMWARE UPDATING
8 - 6
[C] Patch update
Fig.8-6
Notes:
• Since the date and time set in the equipment are recorded in the firmware update log, make sure
that they are correct before updating the firmware.
• Never change the model specific folder name since it is used for identifying the data file when the
ones used for updating multiple models are stored in a USB device.
• Updating of the base version data must be completed in advance when an update of differential
items is performed.
• If the differential items update has failed, update the base version data and then perform the
differential items update again.
• Be sure to perform a standard update if such is required after the board or HDD has been
formatted. The update will fail if the differential items update is performed instead.
• The files for the standard package and the differential items package can be used to update
while they are stored into the same USB device. Moreover, it is also possible to store multiple
files for differential items package into the same USB device.
Important:
• Only the USB devices which meet the following conditions should be used for updating. Note that
updating with any devices other than the above is never guaranteed.
- A combination USB device with a flash memory (to be connected directly to the
USB port) and its capacity is 2GB or more.
- Operation of the USB device used for updating has been confirmed at the input
check of this equipment (Test mode 03). (
P. 3-8 "3.3 Input check (Test mode
- The USB devices which comply with the following standards regulated by USB-IF
(USB Implementers Forum)
Class number:
8 (=08h) (Mass-storage class)
Sub-class number:
6 (=06h) (SCSI transfer command set)
Protocol number:
80 (=50h) (Bulk-Only)
* Almost all general USB devices comply with the above specifications and can be used
for updating. However, the operation in all the Multi Functional Digital Color Systems
and Multi Functional Digital Systems is not necessarily guaranteed since the most of
these devices are developed based on use in a PC environment (Windows or
Macintosh). Therefore, check thoroughly that the device is operational in the equipment
for which the updating will be performed when purchasing it.
• The USB devices complying with USB2.0 can be used for updating.
• Do not update the firmware by any storage device other than a flash memory (such as a USB
connection type memory card reader, CD/DVD drive or hard disk), since it is never guaranteed.
• It is possible to store the model specific update program and the data file for updating directly in
the root directory when you store the updating data file for one specific model in the USB device.
However, if the model specific folder for the same model as that of the data file stored in the root
directory already exists, this will have priority.
Model specific folder name
477_527S
USB device
477_527S
T290HDPWxxxx.tar
T290SFPWxxxx.tar
signartures.sig
Содержание e-Studio477s
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved DISASSEMBLY AND REPLACEMENT 2 6 ...
Страница 214: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved ERROR CODE AND TROUBLESHOOTING 5 110 ...
Страница 288: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved REMOTE SERVICE 7 42 ...
Страница 318: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 8 30 ...
Страница 332: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 9 14 ...
Страница 338: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 10 6 ...
Страница 437: ...Maintenance Utility Operating Manual 42678819FU02 1 38 Maintenance Utility Operating Manual Version 1 1 ...
Страница 480: ......
Страница 481: ......
Страница 482: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...