© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO477S/527S/477SL
ERROR CODE AND TROUBLESHOOTING
5 - 49
5
[F101_4] Partition mount error (The HDD cannot be connected (mounted) caused by damage to
the "/work" partition.)
[F101_10] Partition mount error (The file link error in the “/work” partition.)
Classification
Contents
Other service call
HDD unmounted: Connection of HDD cannot be detected.
Sub-code 4: Partition mount error (The "/work" partition is
damaged.)
Sub-code 10: Partition mount error (The file link error in the “/
work” partition)
Check item
Measures
HDD, SYS board, Setting
1. Turn the power of the equipment OFF and check the
connection of the HDD.
- Connector and harness check
- Check if the connector pins of the HDD are bent.
- Check if HDD for other equipment is not installed.
- Check if SRAM for other equipment is not installed.
2. If the error still occurs after step 1, perform the following.
- Perform [3C] - [5] (Key Backup Restore) and check
that each Key Status is "OK".
- If not, recover the key (copy "SRAM Key Status" to
"FROM Key Status" or vice versa).
3. If the error persists after step 2, perform
[5]+[C]+[POWER]
2. Recovery F/S
3. /work, and
then restart the equipment.
4. If the error persists after step 3, perform
[5]+[C]+[POWER]
3. Initialize HDD
2. /work, and
then restart the equipment.
5. If the error still persists after step 4, perform the
following.
- Perform [3C] - [3] (Format HDD), and then install
"System Software (HD data)" with [49] - [4].
Notes:
The following items will be deleted by performing
[3C] - [3] (Format HDD).
• Message Log
• Job Log
• Spool Data (Print, Email reception)
• Template
If the error persists after performing step 5, perform
step 5 after performing [4]+[C]+[POWER]
1. Revert
factory initial status HDD.
6. If the error persists even after step 5, replace the HDD.
Replacement part
Measure
HDD
SYS board
Содержание e-Studio477s
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved DISASSEMBLY AND REPLACEMENT 2 6 ...
Страница 214: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved ERROR CODE AND TROUBLESHOOTING 5 110 ...
Страница 288: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved REMOTE SERVICE 7 42 ...
Страница 318: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 8 30 ...
Страница 332: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 9 14 ...
Страница 338: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 10 6 ...
Страница 437: ...Maintenance Utility Operating Manual 42678819FU02 1 38 Maintenance Utility Operating Manual Version 1 1 ...
Страница 480: ......
Страница 481: ......
Страница 482: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...