© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO477S/527S/477SL
ERROR CODE AND TROUBLESHOOTING
5 - 79
5
[2D66] Storage capacity full failure during processing
Delete the job in progress or being set or in the HOLD/PRIVATE/PROOF/INVALID, and perform it
again.
Check if the server or local disk has a sufficient space in disk capacity.
Check that there is enough space in the server or local disk.
[2D67] FTP service not available
Check if the setting of FTP service is valid.
[2D68] File sharing service not available
Check if the setting of SMB is valid.
[2D69] NetWare service not available
Check if the Netware setting is enabled.
[2DC1] Power failure
Check if the power cable is connected properly and it is inserted securely.
Check if the power voltage is unstable.
[2E10] USB storage system access abnormality
Turn the power OFF and then back ON. Perform the job in error again. If the error still occurs, first,
check if there are no jobs existing and then perform HDD formatting ([5] + [C] + [POWER] ON ->
[3] -> [1]).
[2E11] Insufficient memory capacity for USB storage
If there is a job in progress, perform the job in error again after the job in progress is finished. If the
error still occurs, turn the power OFF and then back ON, and then perform the job in error again.
[2E12] Message reception error in USB storage
[2E13] Message transmission error in USB storage
Turn the power OFF and then back ON. Perform the job in error again.
[2E14] Invalid parameter for USB storage
If a template is being used, recreate the template. If the error still occurs, turn the power OFF and
then back ON. Perform the job in error again.
[2E15] Exceeding maximum file capacity
Delete some files in the folder. Perform the job in error again.
[2E30] Directory creation failure in USB storage
Check if access privilege to the storage directory is writable. Check if the server or local disk has
sufficient space in its disk capacity.
[2E31] File creation failure in USB storage
Check if access privilege to the storage directory is writable. Check if the server or local disk has
sufficient space in its disk capacity.
[2E32] File deletion failure in USB storage
Turn the power OFF and then back ON. Perform the job in error again. If the error still occurs, first,
check if there are no jobs existing and then perform HDD formatting ([5] + [C] + [POWER] ON ->
[3] -> [1]).
[2E33] File access failure in USB storage
Check if access privilege to the storage directory is writable. Check if the server or local disk has
sufficient space in its disk capacity.
Содержание e-Studio477s
Страница 6: ......
Страница 10: ......
Страница 24: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved DISASSEMBLY AND REPLACEMENT 2 6 ...
Страница 214: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved ERROR CODE AND TROUBLESHOOTING 5 110 ...
Страница 288: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved REMOTE SERVICE 7 42 ...
Страница 318: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 8 30 ...
Страница 332: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 9 14 ...
Страница 338: ...e STUDIO477S 527S 477SL 2013 2016 TOSHIBA TEC CORPORATION All rights reserved EXTERNAL COUNTERS 10 6 ...
Страница 437: ...Maintenance Utility Operating Manual 42678819FU02 1 38 Maintenance Utility Operating Manual Version 1 1 ...
Страница 480: ......
Страница 481: ......
Страница 482: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...