4 – Mixer configuration and settings
Function
Parameter1
Parameter2
Parameter3
Function explanation
Talkback
ON/OFF
Turn the talkback mic on/off. (See “Making
talkback and built-in oscillator settings”
Monitor Source Select
Monitor Select 1-6
Select a specific number for Monitor Select.
MONITOR SELECT buttons” on page
Monitor Control
MUTE
Turn monitoring signal muting on/off. (See “
Monitor MUTE button” on page 50.)
DIM
Turn monitoring signal dimming on/off. (See
Monitor DIM button” on page 50.)
SEND ON/OFF
CH 1-40
ST IN 1-2
FX RTN 1-4
MIX 1-22
MAIN L/R
MIX 1-22
FX 1-4
This turns ON/OFF the SEND from the
module specified with Parameter 1 to the bus
specified with Parameter 2.
The key will light when this setting is on.
NOTE
i
Foot Switch: GPIO-IN:
i
Whe n Mute Group, Talkback, Monitor Control and SEND ON/OFF functions are assigned, the selected function will be activated
while a Low level signal is being input. Moreover, if the same function is assigned to multiple GPIO-IN and/or footswitches, the
function will be activated when any one of those signals is Low level. The function will be deactivated only when all the signals
from the assigned GPIO-IN and/or footswitches are High level (OR operation).
i
When other functions are assigned, the selected function will operate if a Low level signal of 50 ms or longer is input.
i
Snapshots stored with this function are named “USER KEY” followed by a three-digit slot number (for example, “USER KEY 018”).
i
When the Function is set to Snapshot and Parameter 2 is set to No, if Parameter 3 matches the current Snapshot number, the
corresponding USER KEY will light.