4 – Mixer configuration and settings
SYNC CLOCK screen
On this screen, the status of each audio clock is shown and
audio synchronization settings and word clock output jack
output mode settings can be made.
Tap Menu Screen > System Setup > Sync Clock to open this
screen.
1
STATUS display area
This shows the status of each audio clock.
Item
Explanation
SYNC CLOCK
This shows the synchronization status of
this unit with the master clock (Locked/
Unlocked/Regained) and the operation
frequency (96kHz/48kHz/No Signal).
WORD IN
This shows the synchronization status
of this unit with the WORD signal input
through the WORD IN jack (Locked/
Unlocked/Regained) and the operation
frequency (actual measured value/No
Signal).
Dante
This shows the synchronization status
of this unit with the connected Dante
system (Locked/Unlocked/Regained)
and the operation frequency (actual
measured value/No Signal).
SLOT1
These show the names of the expansion
cards in SLOT 1 and 2 and the
synchronization statuses of this unit
with them (Locked/Unlocked/Regained)
and the operation frequency (actual
measured value/No Signal).
SLOT2
2
Sync Clock buttons
These set the synchronization clock frequency of the digital
input and output signals.
The selected button will be highlighted light blue.
Options: 48 kHz, 96 kHz (default)
NOTE
This unit will always operate internally at 96 kHz even when
synchronized to a master clock that is 48 kHz.
3
Clock Master buttons
These set the master clock used by this unit for audio
synchronization. (default: INT)
o
A
4
mark appears on the master clock being used.
o
If the selected master clock is locked, the select button
will be highlighted light blue.
o
If the selected external clock is unlocked, the unit will
operate using the internal clock. In this case the
4
will
be shown on the INT button as the clock in use, while
✖
is shown on the selected button for the unlocked source.
The selected button for the unlocked source will be
highlighted red.
o
If synchronization becomes possible with an external
clock after synchronization with it failed (Regain state),
the
4
will be shown on the INT button as the clock in use,
while is shown on the selected button for the clock in
a regain state. Tap the red-highlighted button with the
mark to open a confirmation message for switching back
to the selected master clock.
Tap the OK button to switch to synchronization with the
selected external clock.
4
WORD OUT Mode buttons
These set the output mode of the WORD THRU/OUT
connector on the back of the unit.
The selected button will be highlighted light blue.
Option
Meaning
WORD OUT/TERM-ON
(default)
This sets the signal output from
the WORD/THRU OUT connector
to WORD OUT and turns WORD
IN connector termination
resistance (75Ω) on.
THRU OUT/TERM-OFF
This sets the signal output from
the WORD/THRU OUT connector
to THRU output of the signal
from the WORD IN connector
and turns WORD IN connector
termination resistance (75Ω) off.
28