BATTERY CHARGE (Manual Control of Battery Charging)
The Ni-MH battery provided with the NRT can be charged automatically. Charging may also be started
and stopped by the user. Charging is automatically initialized whenever the instrument is connected to
the AC supply after at least three hours of battery operation. Charging is indicated by the display of dan-
ger arrow and battery symbol.
Charging can be started any time manually by selecting
BATTERY CHARGE - ON:
UTILity
-
BATTERY
CHARGE:
Manual charging should be carried out whenever the NRT is to be operated without AC supply over a
longer period and there is no possibility of recharging the battery during this period. Charging can how-
ever be stopped prematurely by selecting
OFF
in the charge menu or by switching off the NRT via the
ON/STBY
key.
Occasional charging of partly discharged batteries does not cause any damage. Fully charged batteries
should however not be recharged repeatedly as this may cause damage in the long run.
This menu is only available if Battery Option NRT-B3 is fitted.
Selection
Description
Available
ON
Start charging
NRT-B3
OFF
Terminate charging
NRT-B3
Preset:
none (last setting)
IEC/IEEE command:
:CONTrol:POWer:BATTery:CHARge LOAD
2.5.7
BEEPER (Alarm Message, Acknowledge Signal)
The
UTILity - BEEPER
menu allows the tone generator to be configured in such a way that an acoustic
signal is output in the case of SWR overranging and when a key is pressed.
UTILity
-
BEEPER:
A SWR limit value and a power threshold are to be entered on the NRT (section 2.3.8.2 SWR.ALARM)
so that the SWR alarm can be output acoustically. Keystrokes are acknowledged by a single beep (valid
entry) or a double beep (invalid entry) if the beeper is configured accordingly.
Selection
Description
Available
OFF
SWR.ALARM
The tone generator responds only if the instrument is
switched on/off or the battery is discharged
Like OFF plus output of an SWR alarm
Always
Always
ON
Like OFF plus output of an SWR alarm and acknow-
ledgement of keystrokes
Always
Preset:
SWR.ALARM
IEC/IEEE command:
SYSTem:BEEPer:STATe ON|OFF
ON / OFF
[SENSe<n>:]SWR:SIGNal BEEPer
SWR Alarm
深圳德标仪器
135-1095-0799
Содержание NRT 1080.9506.02/.62
Страница 2: ...深圳德标仪器 135 1095 0799 ...
Страница 4: ...深圳德标仪器 135 1095 0799 ...
Страница 6: ...深圳德标仪器 135 1095 0799 ...
Страница 16: ...深圳德标仪器 135 1095 0799 ...
Страница 18: ...深圳德标仪器 135 1095 0799 ...
Страница 178: ...深圳德标仪器 135 1095 0799 ...
Страница 190: ...深圳德标仪器 135 1095 0799 ...