![Rohde & Schwarz NRT 1080.9506.02/.62 Скачать руководство пользователя страница 152](http://html.mh-extra.com/html/rohde-and-schwarz/nrt-1080-9506-02-62/nrt-1080-9506-02-62_operating-manual_1477860152.webp)
Installation and Removal of Modules
NRT
1080.9506.02
4.14
E-4
4.5.6 Display
Board
Removal:
½
Open the instrument (Section 4.5.1).
½
Remove plastic cover strip on top of the front frame (lift at the edge with a
screwdriver and pull off with caution).
½
Remove the 4 Phillips screws on the front panel and the two Phillips screws in
the middle of the top and bottom sections of the front frame (Fig. 4-6).
½
Withdraw display board from the adapter frame towards the front.
½
Disconnect 32-wire cable W5 (connector X5) from the display.
½
Disconnect 6-wire sensor connector from the Mainboard.
Installation:
To install the display board, proceed in reverse order. The correct position of the
connectors X5 and X71 to X78 is ensured by coding.
4.5.7 Mainboard
Removal:
½
Open the instrument (Section 4.5.1).
½
If fitted, remove options NRT-B1 (4.5.2) and NRT-B3 (4.5.4); see Fig. 4-5.
½
Disconnect all cables from the mainboard (Fig. 4-6).
½
Undo two Phillips screws and remove the two nuts from the connector for the
RS-232 interface (X7).
½
Slightly lift the mainboard on the front side, push it towards the front panel and
remove it from the instrument.
Installation:
To install the mainboard, proceed in reverse order. The correct position of the
connectors is ensured by coding.
深圳德标仪器
135-1095-0799
Содержание NRT 1080.9506.02/.62
Страница 2: ...深圳德标仪器 135 1095 0799 ...
Страница 4: ...深圳德标仪器 135 1095 0799 ...
Страница 6: ...深圳德标仪器 135 1095 0799 ...
Страница 16: ...深圳德标仪器 135 1095 0799 ...
Страница 18: ...深圳德标仪器 135 1095 0799 ...
Страница 178: ...深圳德标仪器 135 1095 0799 ...
Страница 190: ...深圳德标仪器 135 1095 0799 ...