Automatic Measurement (AUTO)
For automatic measurement of the average burst power the video bandwidth
(VID.BW)
for the rectified
signal must be defined. The bandwidths available are sensor-dependent and are diplayed in plain text in
the menu as soon as the setting
AV.BRST
is confirmed in the calling menu. The bandwidths shown in
the figure below – 4 kHz, 200 kHz, and
"FULL"
– can be set with sensors NRT-Z43/44.
"FULL"
means
that the maximum bandwidth of the sensor, i.e. approx. 4 MHz, is used.
CONFig - ENV KEY -
AV.BRST - AUTO- VID.BW:
The bandwidth should be selected as narrow as possible, observing the limits specified for CW bursts in
Table 2-1. The narrow video bandwidth is required to free the rectified signal from the superimposed
modulation, so that only a slightly modulated squarewave pulse sequence is obtained. The highest
measurement accuracy is achieved with duty cycles above 10%. Duty cycles below 1% should be
avoided.
The video bandwidth set in this menu overwrites the settings made in the menus
PEP, CF
and
CCD
F.
IEC/IEEE command:
:
SENSe<n>:FUNCtion[:ON] "POWer:FORWard:AVERage:BURSt"
:
SENSe<n>:BURSt:MODE AUTO
:
SENSe<n>:BANDwidth:VIDeo:FNUMber <f>
<f>
: see Table 2-1, the preset value depends on the sensor used.
Measurement with user-defined parameters (USER)
If an automatic measurement of the average burst power is not possible (power or duty cycle too small),
the burst parameters must be entered manually in the
USER
submenu.
After selecting the
USER
submenu the entry of first the burst width and then the burst period is re-
quested. The selected values must be confirmed with the
SEL(LOCAL)
key.
b)
Entry of burst width:
CONFig - ENV KEY -
AV.BRST - USER - WIDTH:
Unit:
seconds (S)
Preset:
depends on the sensor used
IEC/IEEE command:
:
SENSe<n>:FUNCtion[:ON] "POWer:FORWard:AVERage:BURSt"
:
SENSe<n>:BURSt:MODE USER
:
SENSe<n>: BURSt:WIDTh 10 ms
b)
Entry of burst period:
CONFig - ENV KEY -
AV.BRST - USER - PERIOD:
Unit:
seconds (S)
Preset:
depends on the sensor used
IEC/IEEE command:
as for the burst width but:
:
SENSe<n>: BURSt:PERiod 40 ms
深圳德标仪器
135-1095-0799
Содержание NRT 1080.9506.02/.62
Страница 2: ...深圳德标仪器 135 1095 0799 ...
Страница 4: ...深圳德标仪器 135 1095 0799 ...
Страница 6: ...深圳德标仪器 135 1095 0799 ...
Страница 16: ...深圳德标仪器 135 1095 0799 ...
Страница 18: ...深圳德标仪器 135 1095 0799 ...
Страница 178: ...深圳德标仪器 135 1095 0799 ...
Страница 190: ...深圳德标仪器 135 1095 0799 ...