CMU-K20/21/22/23/24 Connection
Control (Signalling only)
1115.6088.12 6.191
E-12
CONFigure:BSSignal[:CSWitched][:TCH]:MSLot:SCONfig:INDividual
Slot Configuration Individual
<Enable_0>,<Enable_1>, ..., <Enable_7>, <Level_0>, ..., <Level_7>
<Enable_n>
Description of parameters
Def. value
Def. unit
ON | OFF
Enable or disable downlink timeslot no. n
(the MS is instructed to listen to this TS)
see below
–
<Level_n>
Description of parameters
Def. value
Def. unit
FW vers.
–127 dB to +127 dB
Power of CMU in timeslot no. n (the CMU
actually transmits a signal in this TS)
see below
dB
V3.05
Description of command
Sig. State
This command defines the active timeslots slots of the BS signal (default values) and the levels for
the
Individual
level mode (see command
CONFigure:BSSignal[:CSWitched][:TCH]:MSLot:LMODe
on p.
6.190
). All 8 timeslots can be enabled and their levels can be set individually. They are defined
relative to the
Reference Level
set via
CONFigure:BSSignal[:CSWitched][:TCH]:MSLot:RLEVel
(see
p.
6.189
). The level range quoted above is restricted by the condition that the absolute level
(calculated from the reference level and the relative individual levels) must not exceed the level
ranges of the RF connectors.
Example:
With output connector RF2 and a reference level of –85 dBm, the individual timeslot
levels can be set in the range –52 dB to +75 dB, corresponding to an absolute level of
–137 dBm to –10 dBm.
In the default setting, slots 3 and 4 are enabled, both levels are 0 dB. By default, slot no. 3 is also the
main timeslot; see
CONFigure:BSSignal[:CSWitched][:TCH]:MSLot:MTIMeslot
command on p.
6.190
.
Note 1:
The <Enable_n> parameters also apply in used/unused level mode; they overwrite the
parameters in the
CONFigure:BSSignal[:CSWitched][:TCH]:MSLot:SCONfig:UUNused
command.
Note 2: Reserved BCCH Slot
If the control channel mode is set to BATC (see command
CONFigure:BSSignal:CCH[:TX]:MODE
on p.
6.186
),
slots
2 to 6 can be configured as
traffic channels. The settings for slots 0, 1 and 7 are ignored; a query returns BCCH for
slot no. 0.
≠
CEST,
Q: all
Subsystem BSSignal:CCH:AUXTx (Aux Tx Signal)
The subsystem
BSSignal:CCH:AUXTx…
configures the additional RF generator signal Aux Tx (with
option CMU-B95). It corresponds to the Aux TX section in the
BS Signal
tab in the popup menu
Connect. Control
.
CONFigure:BSSignal:CCH:AUXTx:CHTYpe
<Mode>
Aux TX – Channel Type
<Mode>
Description of parameters
Def. value
Def. unit
FW vers.
OFF
BCCH
Aux TX signal switched off
Aux TX signal provides the BCCH
OFF – V3.40
Description of command
Sig. State
This command switches the Aux TX signal on or off.
SON,
SOFF
深圳德标仪器
135-1095-0799
Содержание CMU-K20
Страница 4: ...深圳德标仪器 135 1095 0799 ...
Страница 8: ...深圳德标仪器 135 1095 0799 ...
Страница 10: ...深圳德标仪器 135 1095 0799 ...
Страница 12: ...深圳德标仪器 135 1095 0799 ...
Страница 18: ...深圳德标仪器 135 1095 0799 ...
Страница 24: ...深圳德标仪器 135 1095 0799 ...
Страница 26: ...深圳德标仪器 135 1095 0799 ...
Страница 34: ...深圳德标仪器 135 1095 0799 ...
Страница 58: ...深圳德标仪器 135 1095 0799 ...
Страница 60: ...深圳德标仪器 135 1095 0799 ...
Страница 78: ...深圳德标仪器 135 1095 0799 ...
Страница 286: ...深圳德标仪器 135 1095 0799 ...
Страница 288: ...深圳德标仪器 135 1095 0799 ...
Страница 304: ...深圳德标仪器 135 1095 0799 ...
Страница 632: ...深圳德标仪器 135 1095 0799 ...