Connection Control (Non Signalling only) CMU-K20/K21/K22/K23/K24
1115.6088.12 6.8
E-12
Subsystem DM:CLOCk (Synchronization)
The subsystem
DM:CLOCk
sets a system clock specific to the network. This frequency is set in the tab
Sync.
in the popup menu
Connect. Control
.
SOURce:DM:CLOCk:STATe
<Mode>
REF OUT 2 on/off
<Mode>
Description of parameters
Def. value
Def. unit
FW vers.
ON | OFF
Switch on/off system clock
OFF
–
V1.15
Description of command
This commands switches the system clock specific to the network at the
REF OUT 2
connector on or off.
SOURce:DM:CLOCk:FREQuency <Frequency>
REF OUT 2
<Frequency>
Description of parameters
Def. value
Def. unit
FW vers.
1.219 MHz to 39.000 MHz
Input value for the system clock
13.000
MHz
V1.15
Description of command
This command determines the system clock frequency applied to
REF OUT 2
. The frequency entered is inter-
nally rounded to one of the following discrete values:
39.000 MHz,
19.500 MHz,
13.000 MHz,
9.750 MHz,
7.800 MHz,
6.500 MHz,
5.571 MHz,
4.875 MHz,
4.333 MHz,
3.900 MHz,
3.545 MHz,
3.250 MHz,
3.000 MHz,
2.786 MHz,
2.600 MHz,
2.438 MHz,
2.294 MHz,
2.166 MHz,
2.053 MHz,
1.950 MHz,
1.857 MHz,
1.773 MHz,
1.696 MHz,
1.625 MHz,
1.560 MHz,
1.500 MHz,
1.444 MHz,
1.393 MHz,
1.349 MHz,
1.300 MHz,
1.258 MHz,
1.219 MHz
Subsystem TRIGger (Trigger Mode)
The subsystem
TRIGger
defines the trigger mode. It corresponds to the
Trigger
tab in the
Connection
Control
menu.
TRIGger[:SEQuence]:SOURce
<Source>
Source
<Source>
Description of parameters
Def. value
Def. unit
FW vers.
FRUN
RFPower
IFPower
EXTern
The power measurement is triggered by the TDMA tim-
ing of the GSM input signal
Wideband RF power trigger
Narrow-band IF power trigger
External trigger signal at connector AUX3/4.
FRUN –
V1.15
Description of command
This command defines the source for the trigger event. The settings
RFPower
and
IFPower
require burst signals.
The setting
FRUN
requires burst signals with incorporated training sequence.
深圳德标仪器
135-1095-0799
Содержание CMU-K20
Страница 4: ...深圳德标仪器 135 1095 0799 ...
Страница 8: ...深圳德标仪器 135 1095 0799 ...
Страница 10: ...深圳德标仪器 135 1095 0799 ...
Страница 12: ...深圳德标仪器 135 1095 0799 ...
Страница 18: ...深圳德标仪器 135 1095 0799 ...
Страница 24: ...深圳德标仪器 135 1095 0799 ...
Страница 26: ...深圳德标仪器 135 1095 0799 ...
Страница 34: ...深圳德标仪器 135 1095 0799 ...