Returned values for BDBL
Value range
Def. value
Def. unit
FW vers.
ProgressTime,
BER,
USFBLER
DBLER
CRCErrors,
Status
0.0% to 100.0%
0.000% to 100.000%
0.000% to 100.000%
0.000% to 100.000%
0 to 500
INV | PASS | FAIL | TLOW | IMP
NAN
NAN
NAN
NAN
NAN
INV
%
%
%
%
–
–
V2.00
Description of command
These commands are always queries. They start a bit error rate test in the continuous repetition mode and output
the measurement results (see also detailed explanation of measured values in chapter 4). The results depend on
the measurement mode set via the
CONFigure:RXQuality:BAVerage<nr> :CONTrol
command (RFER,
BER etc.). They are
ProgressTime Relative
progress of the measurement
ClassIIBits
(Residual) bit error rate for class II bits
ClassIbBits
(Residual) bit error rate for class Ib bits
BER
Bit error rate (no distinction between bit classes)
FER
Frame erasure rate
DBLER
Data Block Error Rate
USFBLER
USF block error rate, available for packet-switched channels only (CMU-K42)
CRCErrors
Cyclic redundancy check (CRC) errors
Status Measurement
status
The following messages can be output for the measurement status:
INV Measurement
invalid
invalid
PASS
All tolerances matched
passed
FAIL
Not all tolerances matched
failed
IMP Measurement
impossible, therefore invalid
impossible
深圳德标仪器
135-1095-0799
Содержание CMU-K20
Страница 4: ...深圳德标仪器 135 1095 0799 ...
Страница 8: ...深圳德标仪器 135 1095 0799 ...
Страница 10: ...深圳德标仪器 135 1095 0799 ...
Страница 12: ...深圳德标仪器 135 1095 0799 ...
Страница 18: ...深圳德标仪器 135 1095 0799 ...
Страница 24: ...深圳德标仪器 135 1095 0799 ...
Страница 26: ...深圳德标仪器 135 1095 0799 ...
Страница 34: ...深圳德标仪器 135 1095 0799 ...
Страница 58: ...深圳德标仪器 135 1095 0799 ...
Страница 60: ...深圳德标仪器 135 1095 0799 ...
Страница 78: ...深圳德标仪器 135 1095 0799 ...
Страница 286: ...深圳德标仪器 135 1095 0799 ...
Страница 288: ...深圳德标仪器 135 1095 0799 ...
Страница 304: ...深圳德标仪器 135 1095 0799 ...
Страница 632: ...深圳德标仪器 135 1095 0799 ...