Signalling: POWer[:NORMal] CMU-K20/21/22/23/24
1115.6088.12 6.134
E-12
READ:SUBarrays:POWer[:NORMal][:GMSK][:CURRent]?
Subarray Results
READ:SUBarrays:POWer[:NORMal]:EPSK[:CURRent]?
READ:SUBarrays:POWer[:NORMal][:GMSK]:AVERage?
READ:SUBarrays:POWer[:NORMal]:EPSK:AVERage?
READ:SUBarrays:POWer[:NORMal][:GMSK]:MAXimum?
READ:SUBarrays:POWer[:NORMal]:EPSK:MAXimum?
READ:SUBarrays:POWer[:NORMal][:GMSK]:MINimum?
READ:SUBarrays:POWer[:NORMal]:EPSK:MINimum?
Start single shot measurement and return results
⇒
RUN
FETCh:SUBarrays:POWer[:NORMal][:GMSK][:CURRent]?
FETCh:SUBarrays:POWer[:NORMal]:EPSK[:CURRent]?
FETCh:SUBarrays:POWer[:NORMal][:GMSK]:AVERage?
FETCh:SUBarrays:POWer[:NORMal]:EPSK:AVERage?
FETCh:SUBarrays:POWer[:NORMal][:GMSK]:MAXimum?
FETCh:SUBarrays:POWer[:NORMal]:EPSK:MAXimum?
FETCh:SUBarrays:POWer[:NORMal][:GMSK]:MINimum?
FETCh:SUBarrays:POWer[:NORMal]:EPSK:MINimum?
Read meas. results (unsynchronized)
⇒
RUN
SAMPle:SUBarrays:POWer[:NORMal][:GMSK][:CURRent]?
SAMPle:SUBarrays:POWer[:NORMal]:EPSK[:CURRent]?
SAMPle:SUBarrays:POWer[:NORMal][:GMSK]:AVERage?
SAMPle:SUBarrays:POWer[:NORMal]:EPSK:AVERage?
SAMPle:SUBarrays:POWer[:NORMal][:GMSK]:MAXimum?
SAMPle:SUBarrays:POWer[:NORMal]:EPSK:MAXimum?
SAMPle:SUBarrays:POWer[:NORMal][:GMSK]:MINimum?
SAMPle:SUBarrays:POWer[:NORMal]:EPSK:MINimum?
Read results (synchronized)
⇒
RUN
Ret. values per subrange
Description of parameters
Def. value
Def. unit
FW vers.
–100.0 dB to + 20.0 dB
...
–100.0 dB to + 20.0 dB
BurstPower[1], 1
st
value for burst power
...
BurstPower[x], xth value for burst power
NAN
...
NAN
dB
...
dB
VV2.00
Description of command
These commands are always queries. They output the burst power versus time in a fixed ¼- bit pattern and in the
subranges defined by means of the
CONFigure:SUBarrays:POWer
command. In the default setting of the
configuration command the
READ:SUBarrays..., FETCh:SUBarrays..., and SAMPle:SUBarrays...
command group is equivalent to the
READ:ARRay..., FETCh:ARRay..., and SAMPle:ARRay...
command group described above.
The
CONFigure:SUBarrays:POWer
command defines a maximum of 32 subranges. If one of the statistical
modes
(ARIThmetical, MINimum, MAXimum)
is set, only one value is returned per subrange.
The calculation of
current, average, minimum,
and
maximum
results is explained in chapter 3 (cf.
display mode
).
深圳德标仪器
135-1095-0799
Содержание CMU-K20
Страница 4: ...深圳德标仪器 135 1095 0799 ...
Страница 8: ...深圳德标仪器 135 1095 0799 ...
Страница 10: ...深圳德标仪器 135 1095 0799 ...
Страница 12: ...深圳德标仪器 135 1095 0799 ...
Страница 18: ...深圳德标仪器 135 1095 0799 ...
Страница 24: ...深圳德标仪器 135 1095 0799 ...
Страница 26: ...深圳德标仪器 135 1095 0799 ...
Страница 34: ...深圳德标仪器 135 1095 0799 ...
Страница 58: ...深圳德标仪器 135 1095 0799 ...
Страница 60: ...深圳德标仪器 135 1095 0799 ...
Страница 78: ...深圳德标仪器 135 1095 0799 ...
Страница 286: ...深圳德标仪器 135 1095 0799 ...
Страница 288: ...深圳德标仪器 135 1095 0799 ...
Страница 304: ...深圳德标仪器 135 1095 0799 ...
Страница 632: ...深圳德标仪器 135 1095 0799 ...