CMU-K20/21/22/23/24 Signalling:
POWer[:NORMal]
1115.6088.12 6.125
E-12
The default settings for 8MSK modulation (EDGE channels, keyword
:EPSK
) are given in the table below:
for
Enable
forTable
Start Stop Start
Stop Start Stop
Suffix Enable Time
Time
rel.Level
rel.Level abs.Level abs.Level
Visibility
1
ON
–10.0 symb
–7 ¼ symb
–59.0
1
dB
–59.0
1
dB
–36.0
2
dBm
–36.0
2
dBm
ON
2
ON
–7 ¼ symb
–4 ½ symb
–30.0 dB
–30.0 dB
–17.0
3
dBm
–17.0
3
dBm
ON
3
ON
–4 ½ symb
–2 ¼ symb
–6.0 dB
–6.0 dB
OFF
OFF
ON
4
ON
–2 ¼ symb
+½ symb
+4.0 dB
+4.0 dB
OFF
OFF
ON
5
ON
½ symb
1 ½ symb
+2.4 dB
+2.4 dB
OFF
OFF
ON
6
ON
1 ½ symb
146 ½ symb
+4.0 dB
+4.0 dB
OFF
OFF
ON
7
ON
146 ½ symb
147 ½ symb
+2.4 dB
+2.4 dB
OFF
OFF
ON
8
ON
147 ½ symb
150 ¼ symb
+4.0 dB
+4.0 dB
OFF
OFF
ON
9
ON
150 ¼ symb
152 ½ symb
–6.0 dB
–6.0 dB
OFF
OFF
ON
10
ON
152 ½ symb
155 ¼ symb
–30.0 dB
–30.0 dB
–17.0
3
dBm
–17.0
3
dBm
ON
11
ON
155 ¼ symb
156 ¾ symb
–59.0
1
dB
–59.0
1
dB
–36.0
2
dBm
–36.0
2
dBm
ON
12
OFF
OFF OFF OFF
OFF OFF OFF OFF
...
16
OFF
OFF OFF OFF
OFF OFF OFF OFF
CONFigure:POWer[:NORMal][:GMSK]:LIMit:LINE:LOWer<nr>[:STATic]:ENABle
<Enable>
CONFigure:POWer[:NORMal]:EPSK:LIMit:LINE:LOWer<nr>[:STATic]:ENABle
<Enable>
CONFigure:POWer[:NORMal][:GMSK]:LIMit:LINE:LOWer<nr>[:STATic]
CONFigure:POWer[:NORMal]:EPSK:LIMit:LINE:LOWer<nr>[:STATic]
Lower Limit Line
Parameters for query:
<StartTime>, <EndTime>, <StartRelLevel>, <EndRelLevel>,
<StartAbsLevel>,
<EndAbsLevel>,
<StartVisibility>, <EndVisibility>
for setting:
<StartTime>, <EndTime>, <StartRelLevel>, <EndRelLevel>,
<StartAbsLevel>, <EndAbsLevel>, <Visibility
>
Parameters
Value range
Description of parameters
Def. value
<Enable>
<StartTime>,
<EndTime>,
<StartRelLevel>,
<EndRelLevel>,
<StartAbsLevel>,
<EndAbsLevel>,
<Visibility>
<StartVisib.>
<EndVisib>
ON | OFF
–10 bit to +156 ¾ bit | OFF
–10 bit to +156 ¾ bit | OFF,
–100 dB to 20 dB | OFF,
–100 dB to 20 dB | OFF,
–90 dBm to 50 dBm | OFF,
–90 dBm to 50 dBm | OFF,
ON | OFF
Definition section on/off
Start point of time
End point of time
Start point of level (relative)
End point of level (relative)
Start point of level (absolute)
End point of level (absolute)
Range of limit lines on/off
See
below
Description of command
FW vers.
These commands activate and define lower limit lines for normal bursts. The limit lines are defined
section by section; the suffix <nr> numbers the different ranges of limit lines.
V1.15
Only 1 area is defined in the default setting, another 15 areas can be activated if required. The default settings for
GMSK modulation (keyword
[:GMSK]
) are shown in the table below:
f
or Enable
for Table
Start
Stop
Start
Stop
Start
Stop
Suffix Enable
Time Time rel.Level
rel.Level abs.Level abs.Level
Visibility
1
ON
–10.0 bit
½ bit
OFF
OFF
OFF
OFF
OFF
2
ON
½ bit
147 ½ bit
–1.0 dB
–1.0 dB
OFF
OFF
ON
3
ON
147 ½ bit
156 ¾ bit
OFF
OFF
OFF
OFF
ON
4
OFF
OFF OFF OFF
OFF OFF OFF OFF
...
16
OFF
OFF OFF OFF
OFF OFF OFF OFF
深圳德标仪器
135-1095-0799
Содержание CMU-K20
Страница 4: ...深圳德标仪器 135 1095 0799 ...
Страница 8: ...深圳德标仪器 135 1095 0799 ...
Страница 10: ...深圳德标仪器 135 1095 0799 ...
Страница 12: ...深圳德标仪器 135 1095 0799 ...
Страница 18: ...深圳德标仪器 135 1095 0799 ...
Страница 24: ...深圳德标仪器 135 1095 0799 ...
Страница 26: ...深圳德标仪器 135 1095 0799 ...
Страница 34: ...深圳德标仪器 135 1095 0799 ...
Страница 58: ...深圳德标仪器 135 1095 0799 ...
Страница 60: ...深圳德标仪器 135 1095 0799 ...
Страница 78: ...深圳德标仪器 135 1095 0799 ...
Страница 286: ...深圳德标仪器 135 1095 0799 ...
Страница 288: ...深圳德标仪器 135 1095 0799 ...
Страница 304: ...深圳德标仪器 135 1095 0799 ...
Страница 632: ...深圳德标仪器 135 1095 0799 ...