INSTrument:NSELect
<Channel>
Selects a channel as the active channel.
Parameters:
<Channel>
Number of the channel to be activated. The channel must be
created before using
ON
.
Range:
1, 2, ...
*RST:
1
Example:
CONF:CHAN2:STAT ON; :INST:NSEL?
Create channel no. 2 and select it as the active channel. The
query returns 2.
INSTrument:PORT:COUNt?
Returns the number of test ports (Port 1, Port 2 ...) of the analyzer.
Example:
INST:PORT:COUN?
Return the number of ports of your analyzer.
Usage:
Query only
INSTrument:TPORt:COUNt?
Returns the total number of test ports.
Because the R&S
ZNA doesn't support switch matrices, this is always the same as the
number of analyzer ports (see
Usage:
Query only
8.3.10
MEMory
The
MEMory...
commands control the loaded recall sets of the analyzer.
Storing setups
The
MEMory...
commands do not affect any stored files. Use the
MMEMory...
com-
mands to store and load data and to manage files stored on a mass storage device.
.............................................................................................. 997
................................................................................................ 997
SCPI Command Reference