Command Reference
R&S
®
ZNA
788
User Manual 1178.6462.02 ─ 12
Example:
For NRZ modulated generator signals
CALCulate:EYE:MEASurement:DATA?
returns something
like
'Eye Measurements
Eye Minimum,-102.344 mV,
Eye Maximum,2.699 V,
Eye Base,277.189 µV,
Eye Top,2.597 V,
Eye Mean,1.298 V,
Eye Amplitude,2.596 V,
Eye Height,2.596 V,
Eye Width,10.000 ns,
Bit Period,10.000 ns,
Rise Time,115.000 ps,
Fall Time,115.000 ps,
Jitter Pk-Pk,50.125 ps,
Jitter RMS,0.000 s,
Duty Cycle Dist,0.000 s,
Duty Cycle Pct,0.000 %,
Crossing Percent,50.000 %,
Opening Factor,1.000 ,
SNR,0.000 '
For PAM modulated generator signals a reduced set of mea-
surement results is returned:
'Eye Measurements
Eye Minimum,-2.909 V,
Eye Maximum,2.997 V,
Eye Base,-2.734 V,
Eye Top,2.734 V,
Eye Mean,0.000 V,
Eye Amplitude,5.468 V'
Usage:
Query only
Options:
R&S
ZNA-K20
Manual operation:
See
CALCulate<Chn>:EYE:MEASurement:STATe
<Boolean>
Defines the visibility of the result info field in the related eye diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Boolean>
Options:
R&S
ZNA-K20
SCPI Command Reference