![Rohde & Schwarz 1332.4500.22 Скачать руководство пользователя страница 1036](http://html1.mh-extra.com/html/rohde-and-schwarz/1332-4500-22/1332-4500-22_user-manual_14777821036.webp)
Command Reference
R&S
®
ZNA
1036
User Manual 1178.6462.02 ─ 12
Tip:
*.s<n>p
Touchstone files (<n> = 1, 2, 3, ...) are intended for a complete set of
<n>-port S-parameters. Data export fails if the active channel does not contain the full
set of <n>
2
traces.
Setting parameters:
<Channel>
Channel number in the active recall set. ALL means that a sepa-
rate file is created for each channel in the active recall set.
<TraceFile>
String parameter to specify the name and directory of the cre-
ated trace file. Several file formats for trace files are supported.
The file extensions
*.s<n>p
,
*.csvc
, and
*.dat
for Touch-
stone, ASCII, and Matlab files are mandatory. To generate a
multiport Touchstone file
*.s2p
,
*.s3p...
, the channel must
contain traces for the full set of S-parameters. If no path is
specified the analyzer uses the
C:\Users\Public\Documents\Rohde-Schwarz\ZNA\
Traces
directory.
<FormatInd>
FORMatted | UNFormatted
UNFormatted - unformatted data export specified by the second
optional parameter.
FORMatted - formatted data export (for
*.csv
and
*.dat
files
only).
If the first optional parameter is omitted, the command stores
unformatted data.
<Format>
COMPlex | LINPhase | LOGPhase
COMPlex - complex values (real and imaginary part)
LINPhase - linear magnitude and phase.
LOGPhase - dB-magnitude and phase.
If the second optional parameter is omitted, the command stores
complex data.
<DecSeparator>
POINt | COMMa
POINt - Decimal separator: point.
COMMa - Decimal separator: comma.
If the third optional parameter is omitted, points are used.
<FieldSeparator>
SEMicolon | COMMa | TABulator | SPACe
SEMicolon - Field separator: semicolon
COMMa - field separator: comma.
TABulator - field separator: tabulator.
SPACe - field separator: space.
If the third optional parameter is omitted, semicolons are used.