C h a p t e r 1 0 A L A R M S
7/26/00
INTEGRA Operations Revision A
10-73
20-0200-231 (CR), 20-0200-232 (Std), 20-0200-251 (CD)
Disposition:
The system will go into CLEARING mode and the
alarm will be posted, however, the heat lamp may stay on
depending on the cause of the problem.
GEM ALID: 157
GEM Alarm.
A
LARM
ID: 158
(Enable alarm in
process recipe
screen)
Description:
Brush #1 Process Alarm Timeout
Posting Program:
Brush 1
Alarm Type:
Alarm & Sonalert
Reason:
This alarm indicates that wafer process time in Brush #1
has been exceeded.
Disposition:
The system will go into CLEARING mode and the
alarm is posted. The alarm timeout period can be independently
programmed in the
FIRST BRUSH STATION PROCESS DEFINE
screen. To enable the alarm, set a value larger than
0
in the
“Process Alarm Timeout” parameter. The timeout entered is in
tenths of seconds. A value of
0
disables the alarm.
GEM ALID: 158
GEM Alarm.
A
LARM
ID: 159
(Enable alarm in
process recipe
screen)
Description:
Brush #2 Process Alarm Timeout
Posting Program:
Brush #2
Alarm Type:
Alarm & Sonalert
Reason:
This alarm indicates that wafer process time in Brush #2
has been exceeded.
Disposition:
The system will go into CLEARING mode and the
alarm is posted. The alarm timeout period can be independently
programmed in the
SECOND BRUSH STATION PROCESS DEFINE
screen. To enable the alarm, set a value larger than
0
in the
“Process Alarm Timeout” parameter. The timeout entered is in
tenths of seconds. A value of
0
disables the alarm.
GEM ALID: 159
GEM Alarm.
A
LARM
ID: 160
(Programmable)
Description:
No Recipe Selected
Posting Program:
Monitor
ALCD
ALTX
ON CEID OFF CEID
6
157
Heat lamp failed to turn off
515
516
ALCD
ALTX
ON CEID OFF CEID
6
158 Wafer Delayed In
Brush #1
517
518
ALCD
ALTX
ON CEID OFF CEID
6
159 Wafer Delayed In
Brush #2
519
520
Содержание Synergy Integra
Страница 8: ......
Страница 24: ...1 4 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 38: ...2 14 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 222: ...9 62 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 314: ...10 76 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...