INTEGRA Operations Revision A
7/26/00
20-0200-231 (CR), 20-0200-232 (Std), 20-0200-251 (CD)
Reason:
The operator can set two programmable alarms in the
system when a set number of wafers have been processed. These
alarms are typically used for the notification of a preventative
maintenance event such as a brush change. The alarms can also
be used for any other reasons the operator may want to know
when a certain wafer count is reached (e.g. batch control).
Disposition:
The alarm is posted but processing continues.
GEM ALID: 2
GEM Alarm.
A
LARM
ID: 3
Description:
Maintenance Setpoint #2 Reached
Posting Program:
Monitor
Alarm Type:
Alarm & Sonalert
Reason:
This alarm is posted when the programmed set point has
been reached.
Disposition:
The alarm is posted but processing continues.
GEM ALID: 3
GEM Alarm.
A
LARM
ID: 4
Description:
UV Lamp Failure
Posting Program:
Monitor
Alarm Type:
Alarm & Sonalert
Reason:
This alarm is only valid on systems that support the UV
lamp interface option. The alarm is posted whenever the
UV lamp
sensor shows a failure.
Disposition:
System is put into CLEAR mode. Once all wafers
have finished processing, the DI bypass valve is turned off
allowing DI water to bypass the system.
GEM ALID: 4
GEM Alarm.
A
LARM
ID: 5
Description:
Brush Station #1 Exhaust Failure
Posting Program:
Monitor
Alarm Type:
Alarm & Sonalert
ALCD
ALTX
ON CEID OFF CEID
7
2 Maintenance Setpoint #1 reached.
205
206
ALCD
ALTX
ON CEID OFF CEID
7
3 Maintenance Setpoint #2 reached.
207
208
ALCD
ALTX
ON CEID OFF CEID
6
4 UV Lamp failure.
209
210
Содержание Synergy Integra
Страница 8: ......
Страница 24: ...1 4 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 38: ...2 14 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 222: ...9 62 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 314: ...10 76 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...