C h a p t e r 3 S Y S T E M C O N F I G U R AT I O N
7/26/00
INTEGRA Operations Revision A
3-13
20-0200-231 (CR), 20-0200-232 (Std), 20-0200-251 (CD)
FIRST
BRUSH STATION OUTPUTS (Solenoids/Switches)
LID CLOSED
SENSOR
Hall Effect Sensor
: Located on
the pneumatic cylinder which
operates the Brush Station lid.
Icon is
green
when the lid is completely
CLOSED. The lid must be closed and locked
for processing to continue. Icon is
red
when
the lid is OPEN, with all Brush Station
processing halted.
BRUSH LID
LOCKED SENSOR
Hall Effect Sensor
. Located on
the pneumatic cylinder which
operates the Brush Station lid
lock.
Icon is
green
when the lock is engaged
(locked) and
red
when the lock is
disengaged (unlocked).
A
NOTE:
It is possible for the lock
to be engaged with the lid open.
The system requires both the
lid
closed
and
locked signals
before
processing can be initiated.
BRUSH LID
UNLOCKED
SENSOR
Hall Effect Sensor
. Located on
the pneumatic cylinder which
operates the Brush Station lid
lock.
Icon is
green
when the lock is disengaged
(unlocked) and
red
when the lock is engaged
(locked). See the NOTE in BRUSH LID
LOCKED SENSOR, above.
CHEMICAL
FLOW SENSOR
Flow Switch
: Located in the
Chemical Drawer #1 after the
chemical and chemical
redundant valves, but before
the flow meter
Icon is
green
when there is sufficient
pressure. The icon is
red
and an alarm is
posted if the system requests chemical and
the flow sensor does not detect sufficient
pressure. See “Alarm ID: 134,” on page 10-64.
OUTPUT NAMES
DESCRIPTION
TRANSPORT MOTOR
Motor Controller Circuitry.
Toggles ON and OFF the wafer conveyor
motor in Brush Station #1. Touch the TRANSPORT MOTOR button to
toggle the motor ON
or
OFF.
Icon Status:
Icon is
green
when the motor is
ON
and
red
when it is OFF
.
BRUSH MOTORS
Motor Controller Circuitry.
The brush motors are programmable speed
motors. When the BRUSH MOTOR button is touched, a
NUMBER PAD
displays so that the desired speed for the Brush Station #1 brush motor
can be entered. Enter the speed, then touch
ENTER
.
TOGGLE ROLLERS
Motor Controller Circuitry
. Toggles rollers OPEN (i.e, Accept/Release
Wafer) and toggles rollers CLOSED (i.e., Ready For Wafer).
Icon Status:
The top right corner of the screen displays the current
roller configuration.
ROLLER MOTOR
Motor Controller Circuitry.
The roller motor is a programmable speed
motor. When the ROLLER MOTOR button is touched, a
NUMBER PAD
screen displays so that the desired speed for the Brush Station #1 roller
motor can be entered. Enter the speed, then touch
ENTER
.
SENSOR NAME
TYPE AND LOCATION
FUNCTION
Содержание Synergy Integra
Страница 8: ......
Страница 24: ...1 4 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 38: ...2 14 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 222: ...9 62 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 314: ...10 76 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...