C h a p t e r 1 0 A L A R M S
7/26/00
INTEGRA Operations Revision A
10-71
20-0200-231 (CR), 20-0200-232 (Std), 20-0200-251 (CD)
Posting Program:
Output
Alarm Type:
Alarm & Sonalert
Reason:
This alarm indicates that a wafer is not expected at the
Output Station. It can occur if the slot number that the wafer is
destined to go to, is out of range. The range of slot numbers is 1 to
the value assigned in the MAX_OUTPUT_CASSETTE WAFERS
variable. During wafer recovery, if the wafer slot number cannot be
determined, then the system will assign an invalid slot number (99).
Disposition:
The system is put into STOP mode and the alarm is
posted.
GEM ALID: 152
GEM Alarm.
A
LARM
ID: 153
(Programmable)
Description:
Low Chem Flow in Line 1
Posting Program:
Brush 1
or
Brush 2
Alarm Type:
Alarm & Sonalert
Reason:
This alarm is only valid on systems configured to run the
Six Chemical option. This alarm indicates that the pressure is
below the setpoint for Chemical Line 1. This alarm can only occur
on systems that have the appropriate hardware sensors and
software configuration options installed. The delay time for the
alarm is 10 seconds.
Disposition:
Alarm can be configured by the user to set the
system into CLEARING (default), STOP or DISABLED mode.
GEM ALID: 153
GEM Alarm.
A
LARM
ID: 154
(Programmable)
Description:
Low Chem Flow in Line 2
Posting Program:
Brush 1
or
Brush 2
Alarm Type:
Alarm & Sonalert
Reason:
This alarm is only valid on systems configured to run the
Six Chemical option. This alarm indicates that the pressure is
below the setpoint for Chemical Line 2. This alarm can only occur
on systems that have the appropriate hardware sensors and
software configuration options installed. The delay time for the
alarm is 10 seconds.
ALCD
ALTX
ON CEID OFF CEID
6
152 Unassigned wafer found at output cassette.
505
506
ALCD
ALTX
ON CEID OFF CEID
6
153 Low Chem Flow in Line 1.
507
508
Содержание Synergy Integra
Страница 8: ......
Страница 24: ...1 4 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 38: ...2 14 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 222: ...9 62 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 314: ...10 76 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...