C h a p t e r 1 0 A L A R M S
7/26/00
INTEGRA Operations Revision A
10-65
20-0200-231 (CR), 20-0200-232 (Std), 20-0200-251 (CD)
Reason:
The Brush2 program has detected the absence of
chemical flow after requesting a chemical. The delay time for the
alarm is 10 seconds.
Disposition:
The system is put into CLEARING mode and the
current wafer is processed but may not be processed with
chemicals in the Brush Station. This alarm can only occur on
systems that have the appropriate hardware sensors and
software configuration options installed.
GEM ALID: 135
GEM Alarm.
A
LARM
ID: 136
(Programmable)
Description:
Failure Detected: Brush1
Edge Flow
Sensor
Posting Program:
Brush1
Alarm Type:
Alarm & Sonalert
Reason:
The Brush Station has detected the absence of DI flow
after requesting a DI for edge clean.
Disposition:
The system is put into Clearing or Stop mode. When
the Clearing mode occurs the current wafer continues to be
processed, in this Brush Station, but may not have proper edge
cleaning. This alarm can only occur on systems that have the
appropriate hardware sensors and software configuration.
GEM ALID: 136
GEM Alarm.
A
LARM
ID: 137
(Programmable)
Description:
Failure Detected: Brush2
Edge Flow
Sensor
Posting Program:
Brush2
Alarm Type:
Alarm & Sonalert
Reason:
The Brush Station has detected the absence of DI flow
after requesting a DI for edge clean.
Disposition:
The system is put into Clearing or Stop mode. When
the Clearing mode occurs the current wafer continues to be
processed, in this Brush Station, but may not have proper edge
cleaning. This alarm can only occur on systems that have the
appropriate hardware sensors and software configuration.
GEM ALID: 137
GEM Alarm.
ALCD
ALTX
ON CEID OFF CEID
6
135 Brush 2 Chemical Low Flow Alarm.
469
470
ALCD
ALTX
ON CEID OFF CEID
6
136 Failure Detected: Brush 1
Edge Flow Sensor.
471
472
ALCD
ALTX
ON CEID OFF CEID
6
137 Failure Detected: Brush 2 Edge Flow Sensor.
473
474
Содержание Synergy Integra
Страница 8: ......
Страница 24: ...1 4 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 38: ...2 14 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 222: ...9 62 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 314: ...10 76 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...