10-44
INTEGRA Operations Revision A
7/26/00
20-0200-231 (CR), 20-0200-232 (Std), 20-0200-251 (CD)
A
LARM
ID: 82
Description:
Invalid Output Cassette Mode, Cannot Maintain
Slot/Slot
Posting Program:
Output station
Alarm Type:
Alarm & Sonalert
Reason:
The Output Station can only support Slot-to-Slot modes
that put wafer #1 from the input cassette into slot #1 in the output
cassette. If modes are set that don’t allow this when a new mode
is selected, the system automatically changes itself into
“continuous” cassette mode so that processing can be completed
and the alarm is posted.
Disposition:
None. All operations continue. Output cassette
mode is changed to “continuous.”
GEM ALID: 82
GEM Alarm.
A
LARM
ID: 83
Description:
Output Cassette Mode Set To Continuous
Posting Program:
Output station
Alarm Type:
Alarm & Sonalert
Reason:
When a new cassette is put in, the output cassette mode
is checked to verify that it is in a valid configuration. This alarm
is posted and the cassette mode changed on submersible input
systems if the configuration is invalid.
Disposition:
None. All operations continue. Output cassette
mode is changed to “continuous.”
GEM ALID: 83
GEM Alarm.
A
LARM
ID: 84
Description:
Output Cassette Mode Set To Continuous
Posting Program:
Output station
Alarm Type:
Alarm & Sonalert
Reason:
When a new cassette is put in, the output cassette mode
is checked to verify that it is in a valid configuration. This alarm
is posted and the cassette mode changed on non-submersible
input systems if the configuration is invalid.
ALCD
ALTX
ON CEID OFF CEID
6
82
Invalid Output Cassette Mode, cannot
maintain Slot/Slot.
365
366
ALCD
ALTX
ON CEID OFF CEID
6
83 Output Cassette Mode set to CONTINUOUS.
367
368
Содержание Synergy Integra
Страница 8: ......
Страница 24: ...1 4 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 38: ...2 14 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 222: ...9 62 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 314: ...10 76 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...