C h a p t e r 1 0 A L A R M S
7/26/00
INTEGRA Operations Revision A
10-29
20-0200-231 (CR), 20-0200-232 (Std), 20-0200-251 (CD)
Posting Program:
Spin Station
Alarm Type:
Alarm & Sonalert
Reason:
This alarm is only valid on systems that have the spin
stepper option. When the stepper moves the spindle to the 90
degree position, the
90 degree position
sensor is checked to make
sure the move was made correctly. If the sensor does not detect
the spindle, a retry is performed to attempt the operation again. If
the sensor still does not detect the spindle, the alarm is posted.
This alarm indicates a failure to move to the 90 degree position.
Disposition:
The alarm is posted but processing continues.
GEM ALID: 44
GEM Alarm.
A
LARM
ID: 45
Description:
Time-out Looking For
Spindle Top
Sensor
Posting Program:
Spin Station
Alarm Type:
Alarm & Sonalert
Reason:
This alarm indicates that the
spindle top
sensor did not
detect the spindle after the spindle was sent to the TOP position.
Disposition:
The Spin Station program will not continue until the
spindle top
sensor detects the spindle in the TOP position.
GEM Alarm.
A
LARM
ID: 46
Description:
Time-out In Spin Waiting On Unload
Posting Program:
Spin Station
Alarm Type:
Alarm & Sonalert
Reason:
When the spin process is complete, the spindle is sent to
the TOP position and the Unload Handler is instructed to remove
the wafer. If after a three minute delay the Unload Handler has
not removed the wafer, a test is made to determine the cause. If
the status is “Remove Cassette” (i.e., completed cassette), then
Alarm 91 is posted. If the status is “Waiting On New
Cassette”(i.e., no cassette), then Alarm 90 is posted. If the wafer is
not taken and the Unload Handler is not waiting on a cassette
operation, then Alarm 46 is posted.
ALCD
ALTX
ON CEID OFF CEID
6
44 Spin Stepper failed to rotate to sensor.
289
290
ALCD
ALTX
ON CEID OFF CEID
6
45 Time-out looking for Spindle Top Sensor.
291
292
Содержание Synergy Integra
Страница 8: ......
Страница 24: ...1 4 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 38: ...2 14 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 222: ...9 62 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Страница 314: ...10 76 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...