594
System Parameters
Appendix D
1077
(4215)
1090
(4240)
10A9
(4265)
10C2
(4290)
R
Origin
search
method
0000
0001
(1)
1078
(4216)
1091
(4241)
10AA
(4266)
10C3
(4291)
R
Origin
search
direction
0000
0000
(0)
1079
(4217)
1092
(4242)
10AB
(4267)
10C4
(4292)
R
Origin
decelera-
tion
method
0000
0000
(0)
107A
(4218)
1093
(4243)
10AC
(4268)
10C5
(4293)
R
Origin
proximity
input logic
0000
0000
(0)
107B
(4219)
1094
(4244)
10AD
(4269)
10C6
(4294)
R
Wiring
check
0000
0001
(1)
Address
R/W
Name
Description
Default
setting
Top: L + 1,
Bottom: L
MC221
MC421
X
Y
Z
U
Specifies the method to search for the origin.
X = 0: Origin mode when power is turned ON.
X = 1: Limit reverse mode
X = 2: Single direction mode
0
0
0
0
0
0
0
X
L+1
L
15
0015
03
00
0
0
0
0
0
0
L+1
L
15
0015
03
00
Origin search direction
11 08
Specifies the phase-Z detection direction
and origin search start direction for an origin
search. If the origin search start direction is
set to 1, then the search direction will be
opposite the Z-phase detection direction
only if the origin proximity signal input and
CW/CCW limit signal input all turn OFF.
X = 0: Same as the phase-Z detection
direction, X = 1: Opposite the phase-Z
detection direction
Phase-Z Detection Direction
Specifies the phase-Z detection direction.
0: Positive; 1: Negative
Origin Search Direction
Phase-Z detection direction
0
0
0
0
0
0
L+1
L
15
00 15
03
00
Origin deceleration method
CW/CCW deceleration method
CW/CCW deceleration method
11 08
Specifies the deceleration method when the
CW or CCW limit input signal is detected.
X = 0: Accumulate pulses to stop, X = 1:
Decelerate to a stop
Origin deceleration method
Specifies the origin deceleration method.
0: Use the origin proximity input signal.
1: Use the limit input signal for the origin
proximity input signal.
Specifies the origin proximity input logic.
X = 0: Normally open.
X = 1: Normally closed.
0
0
0
0
0
0
0
X
L+1
L
15
00 15
03
00
Specifies whether the wiring check function is
used.
X = 0: The wiring check function is not used.
X = 1: The wiring check function is used.
0
0
0
0
0
0
0
X
L+1
L
15
0015
03
00
Содержание CS1W-MC221 -
Страница 1: ...Motion Control Units Cat No W359 E1 04 CS1W MC221 V1 421 V1 OPERATION MANUAL ...
Страница 2: ...CS1W MC221 V1 421 V1 Motion Control Units Operation Manual Revised February 2008 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 11: ...xii ...
Страница 15: ...xvi ...
Страница 19: ...xx ...
Страница 27: ...xxviii Conformance to EC Directives 6 ...
Страница 133: ...106 Installation Section 2 2 2 2 4 Dimensions CS1W MC421 CS1W MC221 ...
Страница 173: ...146 Connecting Peripheral Devices Section 2 7 ...
Страница 227: ...200 Command Area Section 3 6 ...
Страница 351: ...324 Interface Specifics Section 5 4 ...
Страница 513: ...486 Absolute Encoder Interface Specifications Section 9 7 ...
Страница 575: ...548 Error Log Section 12 6 ...
Страница 589: ...562 Performance Appendix A ...
Страница 655: ...628 Control Bit Flag Timing Charts Appendix E ...
Страница 683: ...656 Origin Search Patterns Appendix F ...
Страница 685: ...658 Encoder Divider Rate and Rotation Speed for OMRON Servo Drivers Appendix G ...