208
Data Transfer and Storage: Overview
Section 4-1
S+1:
Always 0000 hex
S+2:
The address of the first source word for position data to be
transferred. Specifies the first source address in internal MC
Unit RAM for position data that will be transferred.
Range: 0000 to 07CF hex (0 to 1999)
S+3:
Always 0000 hex
S+4:
The first destination address for transferred position data.
Specifies the first word address in the DM or EM Area that will
store the position data transferred from the MC Unit.
S+5:
The transfer source area designation (DM or EM).
Specifies the DM or EM area that will store position data.
X = 0: DM Area, X = 1 to D: Corresponds to banks 0 to C in
the EM Area
3.
Execute the IOWR instruction to transfer position data to the MC Unit.
4.
Each position requires three words.
4-1-5
Data Storage
Transferred position data and system parameters are written to internal MC
Unit memory where they will be used for operation, but they will be lost if MC
Unit power is turned OFF or the Unit is restarted. The data must be saved in
flash memory using the command area to keep the data in the MC Unit per-
manently. Refer to
4-3 Saving Data
for more details on storing data in flash
memory.
Once data has been saved, it is stored in internal MC Unit flash memory
where it will be available the next time MC Unit power is turned ON or the Unit
is restarted. Position data and system parameters that are simply transferred
without being saved will be lost when MC Unit power is turned OFF or the Unit
is restarted.
Refer to
4-1-2 Types of Data
for information on transferring and saving data
from the CX-Motion, CPU Unit, or a Teaching Box.
Note
1.
Data that has been saved is automatically read to internal memory from
flash memory when MC Unit power is turned ON or the Unit is restarted.
2.
Do not turn OFF MC Unit power or restart the Unit while data is being
saved. Doing so may damage the flash memory in the MC Unit.
3.
Flash memory has a limited service life. Data can be written up to 100,000
times.
CPU Unit
Transfer
MC Unit
Saved
Flash memory
Program
System parameters
Position data
Program
System parameters
Transfer
Transfer
Teaching Box
CX-Motion
RAM
Position data
Saved on
floppy
disks or
hard disks.
When MC
Unit power is
turned ON or
the Unit is re-
started.
Содержание CS1W-MC221 -
Страница 1: ...Motion Control Units Cat No W359 E1 04 CS1W MC221 V1 421 V1 OPERATION MANUAL ...
Страница 2: ...CS1W MC221 V1 421 V1 Motion Control Units Operation Manual Revised February 2008 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 11: ...xii ...
Страница 15: ...xvi ...
Страница 19: ...xx ...
Страница 27: ...xxviii Conformance to EC Directives 6 ...
Страница 133: ...106 Installation Section 2 2 2 2 4 Dimensions CS1W MC421 CS1W MC221 ...
Страница 173: ...146 Connecting Peripheral Devices Section 2 7 ...
Страница 227: ...200 Command Area Section 3 6 ...
Страница 351: ...324 Interface Specifics Section 5 4 ...
Страница 513: ...486 Absolute Encoder Interface Specifications Section 9 7 ...
Страница 575: ...548 Error Log Section 12 6 ...
Страница 589: ...562 Performance Appendix A ...
Страница 655: ...628 Control Bit Flag Timing Charts Appendix E ...
Страница 683: ...656 Origin Search Patterns Appendix F ...
Страница 685: ...658 Encoder Divider Rate and Rotation Speed for OMRON Servo Drivers Appendix G ...