87
Overview of Version 1 Upgrades
Section 1-12
G execution
control
Reading timing of
indirectly specified
data
Read when prereading.
Read for all linked G32 commands when the first
G32 command is executed.
Single block opera-
tion
Blocks executed one at a
time.
All blocks with linked G32 commands executed
together.
Forced Block End Bit Only block currently being
executed is ended.
Note
Ending is placed on
hold for integrated sec-
tions.
All blocks with linked G32 commands ended.
G74
Only block currently being
executed is ended.
Note
Ending is placed on
hold for integrated sec-
tions.
All blocks with linked G32 commands ended.
G75
Only the next block is skipped. All blocks with linked G32 commands skipped.
Link (pass) condition Executing the next G32 for the
same axis and rotating direc-
tion within the minimum pass
time.
Programming a G32 command for the same axis
and rotating direction in the next block.
Note
Comments can be entered.
Maximum number of
links (passes)
No limit.
100 blocks max. (not including comment blocks)
Operating mode
All settings are valid.
Pass operation is possible for
linear interpolation or traverse
operations for the same axis
and rotating direction.
Operation is performed in Stop Mode regardless
of the operating mode (like G00).
Execution block
number (status)
The preread block number is
given.
The number of the block currently being exe-
cuted is given.
Note
If any errors are detected before the start
of operation, the number of the block with
the error is given.
Pause/continue
operation
Continuous execution is pos-
sible, but if the axis is moved
while operation is stopped,
continuous operation cannot
be continued.
Note
The request is placed
on hold for integrated
sections.
Continuous execution is possible, but if the axis
is moved while operation is stopped, continuous
operation cannot be continued.
Software limit checks
(traverse axis)
Check when prereading is
performed.
All blocks checked at beginning of linked G32
commands.
Overrides
Read when prereading and
cannot be changed during
operation.
Can be changed in real time except when decel-
erating to target position.
Classification
Functionality
Normal traverse operation
in Pass Mode (for reference)
Linked traverse (customized function)
Содержание CS1W-MC221 -
Страница 1: ...Motion Control Units Cat No W359 E1 04 CS1W MC221 V1 421 V1 OPERATION MANUAL ...
Страница 2: ...CS1W MC221 V1 421 V1 Motion Control Units Operation Manual Revised February 2008 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 11: ...xii ...
Страница 15: ...xvi ...
Страница 19: ...xx ...
Страница 27: ...xxviii Conformance to EC Directives 6 ...
Страница 133: ...106 Installation Section 2 2 2 2 4 Dimensions CS1W MC421 CS1W MC221 ...
Страница 173: ...146 Connecting Peripheral Devices Section 2 7 ...
Страница 227: ...200 Command Area Section 3 6 ...
Страница 351: ...324 Interface Specifics Section 5 4 ...
Страница 513: ...486 Absolute Encoder Interface Specifications Section 9 7 ...
Страница 575: ...548 Error Log Section 12 6 ...
Страница 589: ...562 Performance Appendix A ...
Страница 655: ...628 Control Bit Flag Timing Charts Appendix E ...
Страница 683: ...656 Origin Search Patterns Appendix F ...
Страница 685: ...658 Encoder Divider Rate and Rotation Speed for OMRON Servo Drivers Appendix G ...