610
System Parameters
Appendix D
Command Area Data Configuration
In the table, W means the data can be written only and R/W means the data
can be read and written. The CS1W-MC221 has only X and Y axes and tasks
1 and 2. In the address column, the top numbers are hexadecimal values and
the bottom numbers in parenthesis () are decimal values.
Address
R/W
Name
Description
MC221
MC421
17D4
(6100)
17D4
(6100)
R/W
Writing position
data to the flash
memory
17D5
(6101)
17D5
(6101)
R/W
Writing system
parameters to flash
memory
Writes system parameters to flash memory. The meaning and usage
here is the same as writing position data to flash memory.
17D6
(6102)
17D6
(6102)
W
Writing position
data
0
0
0
0
0
0
0
X
L+1
L
15
00 15
00
03
Writes position data to the flash memory.
Writes position data to flash memory. Set this area at 1 to write
posi-tion data to flash memory. The following appears after the
data is read.
X = 0: Write has not been executed or it has been completed.
X = 1: Data is being written or a write error has occurred.
The area will be set to 0 when the data has been written.
L+0
L+1
L+2
L+3
L+4
L+5
15
12 11
08 07
04 03
00
0
0
0
0
0
0
0
0
First source word number for transferred position data
Transfer source area designation (DM or EM)
First destination address for transferred position data
This parameter can transfer a maximum of 2,000 positions to an MC Unit at
one time. It executes by specifying the address (17D6 Hex) with the first oper-
and of the IOWR instruction. The address of the word that will be transferred
is written first in DM or EM.
Range: 0003 to 1770 Hex (3 to 6,000, 3 words/data item)
Total number of words written
Specifies the total number of words for the 1 to 2,000 positions in multiples of
three since each position data item is formed from three words.
First source word number for transferred position data
Specifies the address of the first word in the DM or EM area storing position
data that will be transferred.
Transfer source area designation
Specifies the DM or EM area storing position data that will be transferred.
X = 0: DM area, X = 1 to D: Corresponds to banks 0 to C in the EM area
First destination address for transferred position data
Specifies the first destination address number in MC Unit internal RAM for
the transferred position data.
Range: 0000 to 07CF Hex (0 to 1999)
Total number of words written
Содержание CS1W-MC221 -
Страница 1: ...Motion Control Units Cat No W359 E1 04 CS1W MC221 V1 421 V1 OPERATION MANUAL ...
Страница 2: ...CS1W MC221 V1 421 V1 Motion Control Units Operation Manual Revised February 2008 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 11: ...xii ...
Страница 15: ...xvi ...
Страница 19: ...xx ...
Страница 27: ...xxviii Conformance to EC Directives 6 ...
Страница 133: ...106 Installation Section 2 2 2 2 4 Dimensions CS1W MC421 CS1W MC221 ...
Страница 173: ...146 Connecting Peripheral Devices Section 2 7 ...
Страница 227: ...200 Command Area Section 3 6 ...
Страница 351: ...324 Interface Specifics Section 5 4 ...
Страница 513: ...486 Absolute Encoder Interface Specifications Section 9 7 ...
Страница 575: ...548 Error Log Section 12 6 ...
Страница 589: ...562 Performance Appendix A ...
Страница 655: ...628 Control Bit Flag Timing Charts Appendix E ...
Страница 683: ...656 Origin Search Patterns Appendix F ...
Страница 685: ...658 Encoder Divider Rate and Rotation Speed for OMRON Servo Drivers Appendix G ...