546
Error Log
Section 12-6
12-6 Error Log
Important errors detected at the MC Unit are saved in non-volatile memory.
These records can be accessed during maintenance and inspection to see
what kinds of errors have been occurring, and how often. The error log can be
read using the CX-Motion.
The following table shows the kinds of errors that are saved in the error log.
0057
(0087)
MPG ratio overflow
(MPG FACTOR OVER)
The MPG’s ratio (factor) is too great, so the command value
cannot occur. Reduce the MPG ratio or the frequency of the
pulses from the MPG. (Turn the MPG a little slower.)
Deceleration
stop
0058
(0088)
Feedback pulse error
(FEEDBK PULSE ERR)
The feedback pulses exceeded 625,000 pps or a task error
occurred while the absolute encoder’s data was being read
and the read was cancelled.
The encoder dividing ratio set in the Servo Driver parameters
is wrong.
When using the U Series, check the setting of Cn-0A.
When using the W Series, check the setting of Pn201.
When using the G Series, check the setting of Pn44 and set
Pn45 to 0.
The excessive feedback pulse frequency could be caused by
a broken encoder cable, encoder error, or noise.
Take appropriate countermeasures and try again.
Remove the causes that have caused the task error.
Emergency stop
Code
Error
Error processing
Stop method
Error code (hex)
Error
Processing
0001
PLC watchdog timer error
Follow the instructions in the applicable PLC manual.
0002
PLC service monitor error
May be caused by the following:
An end refresh prohibition is set by the CPU Unit.
The CPU Unit scan time is too short.
Take the following countermeasures:
Clear the end refresh prohibition.
Lengthen the CPU Unit scan time.
0006
Other CPU Unit error
Make adjustments at the CPU Unit.
000E
CPU bus error
Check whether the MC Unit is securely mounted to the
Backplane. If the error persists, the CPU Unit or the
Backplane may be defective. Replace the CPU Unit or the
Backplane.
000F
PLC initialization processing error
May be caused by the following:
The unit number is not correctly set.
The unit number is allocated to another
Special I/O Unit.
Set the unit number correctly and power up again.
0015
Fatal PLC error
Follow the instructions in the applicable PLC manual.
0016
Non-fatal PLC error
Follow the instructions in the applicable PLC manual.
0108
Routing error
These errors do not normally occur. If they do occur,
contact an OMRON representative.
010d
Routing error
010e
Routing error
0118
Illegal packet error
0124
Routing error
0602
Memory corruption
An error has occurred at the flash memory or EEPROM. If
this error occurs frequently, replace the MC Unit.
0310
System parameter corruption
Refer to the system error code 0001 hex.
0311
Program corruption
Refer to the system error code 0003 hex.
Содержание CS1W-MC221 -
Страница 1: ...Motion Control Units Cat No W359 E1 04 CS1W MC221 V1 421 V1 OPERATION MANUAL ...
Страница 2: ...CS1W MC221 V1 421 V1 Motion Control Units Operation Manual Revised February 2008 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 11: ...xii ...
Страница 15: ...xvi ...
Страница 19: ...xx ...
Страница 27: ...xxviii Conformance to EC Directives 6 ...
Страница 133: ...106 Installation Section 2 2 2 2 4 Dimensions CS1W MC421 CS1W MC221 ...
Страница 173: ...146 Connecting Peripheral Devices Section 2 7 ...
Страница 227: ...200 Command Area Section 3 6 ...
Страница 351: ...324 Interface Specifics Section 5 4 ...
Страница 513: ...486 Absolute Encoder Interface Specifications Section 9 7 ...
Страница 575: ...548 Error Log Section 12 6 ...
Страница 589: ...562 Performance Appendix A ...
Страница 655: ...628 Control Bit Flag Timing Charts Appendix E ...
Страница 683: ...656 Origin Search Patterns Appendix F ...
Страница 685: ...658 Encoder Divider Rate and Rotation Speed for OMRON Servo Drivers Appendix G ...