background image

■ EP D T-088■

 

MODEL GD-26G, GD-27G 

Pressure Reducing Valve 

PRODUCT MANUAL 

Thank you very much for choosing the Yoshitake’s product. To ensure the correct and safe use of the 
product, please read this manual before use. This manual shall be kept with care for future reference. 
The symbols used in this manual have the following meanings.   
 

  Warning 

This symbol indicates a potentially hazardous situation that, if not avoided, 
could result in death or serious injury. 

  Caution 

This symbol indicates a hazardous situation that, if not avoided, may result in 
minor or moderate injury or may result in only property damage. 

 

Table of Contents 

 
 

1. Specifications 

1.1 Specifications ····················································· 1   

1.2 Nominal size selection ······································ 2 - 3   

1.3 Flow rate characteristics chart ································ 3 

1.4 Pressure characteristics chart ································· 3 

2. Dimensions and weights ········································· 4 - 5 

3. Operation ································································ 6 

4. Maintenance and inspection 

4.1 Precaution for operation ········································ 7 

4.2 Warning and caution for operation ··························· 8 

4.3 Piping example ··················································· 8 

4.4 Adjusting procedure ············································· 8 

4.5 Troubleshooting ·················································· 9 

4.6 Warning for disassembly and inspection ················· 10 

4.7 Disassembly ····················································· 10 

5. Exploded view ··················································· 11 - 12 

After Sales Service 

 
 
 
 
 
 
 
 
 
 
 

 
 
 

Содержание GD-26G

Страница 1: ...ious injury Caution This symbol indicates a hazardous situation that if not avoided may result in minor or moderate injury or may result in only property damage Table of Contents 1 Specifications 1 1...

Страница 2: ...r less Reduced pressure A 0 05 0 35 MPa B 0 30 0 70 MPa Min differential pressure 0 05 MPa Max pressure reduction ratio 10 1 Application temperature 5 90 C Material Body Bronze Valve seat Bronze Valve...

Страница 3: ...tively first find intersection point A of the inlet pressure P1 of 0 3 MPa and the reduced pressure P2 of 0 2MPa Trace down vertically from the intersection point to find intersection point B with the...

Страница 4: ...art shows variation in the reduced pressure when the inlet pressure of 0 60 MPa is changed between 0 15 MPa and 1 0 MPa after the reduced pressure is set at 0 10 MPa Q Max Fluid flow rate m3 h standar...

Страница 5: ...cap 4 Spindle 12 Diaphragm shell 5 Retainer 13 Spring plate 6 O Ring 14 Adjusting screw 7 Disc cover 15 Adjusting spring 8 Disc GD 26G mm Nominal size d L H1 H Weight kg 15A Rc 1 2 115 37 5 159 5 1 6...

Страница 6: ...t kg d D C t n h 25A 160 41 170 25 125 90 14 4 19 5 1 32A 200 57 224 32 135 100 16 4 19 7 5 40A 200 57 224 40 140 105 16 4 19 7 7 50A 220 61 239 5 50 155 120 16 4 19 10 9 65A 220 77 329 65 175 140 18...

Страница 7: ...ondary side pressure When the sluice valve on the secondary side is closed the pressure applied to the diaphragm 9 increases overcomes the load of the adjustment spring 15 and the disc 8 closes Gradua...

Страница 8: ...stment 6 If a quick operating valve such as a solenoid valve is installed place it at a distance of at least 3 meters from the product Failure to follow this notice may result in malfunction or a dras...

Страница 9: ...ping example 4 4 Adjusting procedure Following a wrong adjusting procedure may cause hunting scale problems or other problem and can heavily damage the main parts of the valve To avoid these problems...

Страница 10: ...he O ring 3 The diaphragm 9 is damaged 3 Replace the diaphragm 4 There is a leakage from the globe valve of the by pass line 4 Repair or replace the globe valve Abnormal sound 1 The nominal size of th...

Страница 11: ...ssure in the piping completely and check if pressure is 0 MPa by pressure gauge 2 Remove the domed cap nut turn the adjusting screw 14 counterclockwise and set the spring 15 free no load 3 Remove the...

Страница 12: ...11 EPD T 088 5 Exploded view Nominal size 15A 50A...

Страница 13: ...12 EPD T 088 Nominal size 65A 100A...

Страница 14: ...product Yoshitake supplies the repair parts for 5 years otherwise individually agreed 3 This warranty does not cover the damage due to any of below 1 Valve seat leakage or malfunction caused by forei...

Отзывы: