Problems for network or remote users /
627
N0130943 02
Modular ICS 7.1 Installer Guide
Dialed DISA number gets ringback instead of
stuttered dial tone
The remote caller has dialed a DISA number, but has instead
reached a target line, or has been routed to the prime telephone
for the auto-answer trunk. The Norstar system has mapped the
incoming digits from a switch onto a target line, or has been
unable to map the digits anywhere.
Solution
1. Verify that the switch is sending the correct number of
digits for the Received number length defined in your
system.
2. Verify all the digit strings that the switch should be
sending.
3. Check that you have defined the correct DISA DN for your
system.
4. Make sure that the published telephone numbers for your
network are correct.
Dialed DISA number gets dial tone instead of
stuttered dial tone
Possible problem
The remote caller has dialed a DISA number, but has reached
the Norstar system instead. The Norstar system has mapped
the incoming digits from a switch onto the Auto DN.
Solution
1. Verify that the switch is sending the correct number of
digits for the Received number length defined in your
system.
2. Verify all the digit strings that the switch should be
sending.
Содержание Modular ICS 7.1
Страница 2: ......
Страница 46: ...46 How to use this document Modular ICS 7 1 Installer Guide N0130943 02...
Страница 72: ...72 Welcome to ISDN Modular ICS 7 1 Installer Guide N0130943 02...
Страница 102: ...102 Remote system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 108: ...108 Controlling system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 192: ...192 ETSI MCDN and Network features Modular ICS 7 1 Installer Guide N0130943 02...
Страница 290: ...290 Modular ICS 7 1 Installer Guide N0130943 02...
Страница 582: ...582 Link Status Modular ICS 7 1 Installer Guide N0130943 02...
Страница 586: ...586 Usage Metrics Modular ICS 7 1 Installer Guide N0130943 02...