Connecting the wiring /
285
N0130943 02
Modular ICS 7.1 Installer Guide
For an explanation about port numbering, see
Port numbering on the wiring charts
on page 260.
For CCI connections in Service column: NC1 stands for the normally closed relay and Com1, the common relay.
CCI signaling is not supported by all carriers. For carriers or installations that do not use CCI signaling, the CCI and ET
connections should be treated as “no connection”. CCI wiring is a non-standard wiring arrangement which has been
submitted to the DOC.
DID supervisory signaling
This equipment returns supervisory signals to the public
switched telephone network (PSTN) when the DID calls are:
•
answered by the called telephone
•
answered by the attendant
•
routed to a customer controlled recorded announcement
•
routed to a dial prompt
This equipment is designed to return supervisory signals on all
DID calls forwarded through the system back to the PSTN
within 20 seconds of call forwarding being initiated.
Emergency transfer conditions
Every DID Trunk Cartridge has a Control Circuit Interface
(CCI) which should be connected directly to the central office
for monitoring purposes.
If the Norstar system loses power or the microcontroller on the
DID Trunk Cartridge malfunctions, the CCI signals the central
office that it can no longer handle DID calls. The central
21
Blue-Violet
X11
R
11
47
Violet-Orange
X12
T
12
22
Orange-Violet
X12
R
12
48
Violet-Green
----
No connection
----
23
Green-Violet
----
No connection
----
49
Violet-Brown
----
No connection
----
24
Brown-Violet
----
No connection
----
50
Violet-Slate
----
ET
----
25
Slate-Violet
----
ET
----
Trunk Module with DID Trunk Cartridges (Continued)
TC Slot
Pin
Wire color
Port
Service
Line
Содержание Modular ICS 7.1
Страница 2: ......
Страница 46: ...46 How to use this document Modular ICS 7 1 Installer Guide N0130943 02...
Страница 72: ...72 Welcome to ISDN Modular ICS 7 1 Installer Guide N0130943 02...
Страница 102: ...102 Remote system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 108: ...108 Controlling system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 192: ...192 ETSI MCDN and Network features Modular ICS 7 1 Installer Guide N0130943 02...
Страница 290: ...290 Modular ICS 7 1 Installer Guide N0130943 02...
Страница 582: ...582 Link Status Modular ICS 7 1 Installer Guide N0130943 02...
Страница 586: ...586 Usage Metrics Modular ICS 7 1 Installer Guide N0130943 02...