534
/ Port/DN status
Modular ICS 7.1 Installer Guide
N0130943 02
Checking the state of the device
Installer password required
From the Norstar device identification display.
1. Press
STATE
.
The display shows one of the states listed in the table that
follows. If you want, you can disable or enable the device.
Refer to
Disabling a device
on page 535 or
Examples of
display messages
on page 535.
2. Press
OK
to return to the device identification display.
How the device state is shown on the display
Display
State of device
Busy
DISABLE
OK
The device is in use.
Disabling...
OK
The device is being disabled.
Enabling...
OK
The device is being enabled.
Idle
DISABLE
OK
The device is not in use.
Unequipped
DISABLE
OK
There is no device connected to that port.
Disabled by user
ENABLE
OK
The device has been disabled by
someone running a Maintenance session.
Disabled by sys.
ENABLE
OK
The device has been disabled by the
system because it is faulty or because a
test is running.
Not available
DISABLE
OK
There is no state available.
Содержание Modular ICS 7.1
Страница 2: ......
Страница 46: ...46 How to use this document Modular ICS 7 1 Installer Guide N0130943 02...
Страница 72: ...72 Welcome to ISDN Modular ICS 7 1 Installer Guide N0130943 02...
Страница 102: ...102 Remote system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 108: ...108 Controlling system access Modular ICS 7 1 Installer Guide N0130943 02...
Страница 192: ...192 ETSI MCDN and Network features Modular ICS 7 1 Installer Guide N0130943 02...
Страница 290: ...290 Modular ICS 7 1 Installer Guide N0130943 02...
Страница 582: ...582 Link Status Modular ICS 7 1 Installer Guide N0130943 02...
Страница 586: ...586 Usage Metrics Modular ICS 7 1 Installer Guide N0130943 02...